ELECTRICAL INSTRUCTIONS
A.Before your new unit is connected to a power supply, check the incoming voltage with a voltmeter. If anything less than 100% of the rated voltage for operation is noted, correct immediately.
True requires that a sole use circuit be dedicated for the unit. Failure to do so voids warranty.
WARNING
Compressor warranties are void if compressor burns out due to low voltage.
WARNING
Power supply cord ground should not be removed!
STARTUP
A.The compressor is ready to operate. Plug in the cooler.
B.The refrigerator is designed to maintain cabinet temperatures of 38˚F to 40˚F (3.3˚C to 4.4˚C).
C.Excessive tampering with the control could lead to service difficulties. Should it ever become necessary to replace temperature control, be sure it is ordered from your True dealer or recommended service agent.
D.Good air flow in your True unit is critical. Be careful to load product so that it neither presses against the back wall, nor comes within two inches of the evaporator housing. Refrigerated air off the coil must circulate down the back wall.
NOTE
If the cooler is disconnected or shut off, wait five minutes before starting again.
Temperature Control and light switch are locat- ed next to each other on the interior ceiling of the cabinet behind the light and cabinet fan.
RECOMMENDATION
Before loading product we recommend you run your True unit empty for two to three days. This allows you to be sure electrical wiring and installation are correct and no shipping damage has occurred. Remember, our factory warranty does not cover product loss!
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial number for your cooler. If at any time during the life of your cooler, a part is needed, you may obtain this part by furnishing the model number and serial number to the company from whom you purchased the cooler. Call
The evaporator drain pan is located inside the refrigerator and it needs to be manually drained