CONDENSER COIL

a. Turn off unit at power switch. Disconnect power to unit. b. Remove rear grill.

c. Clean condenser by either brushing off with stiff wire brush or vacuuming with wet/dry vacuum. Condenser is black and looks like a radiator. This should be cleaned every month or as necessary. Keeping clean allows for maximum cooling of unit and long life of compressor.