Turbosound LMS-D4 user manual OP1+3 Sub Mode = Stereo, OP1+3 Sub Limiter = +5dBu, Peak Limiters

Models: LMS-D4

1 17
Download 17 pages 26.32 Kb
Page 12
Image 12

user manual

LMS-D4

3) Sub-bass channels operation mode

OP1+3 Sub

Mode = Stereo

The possible values are ‘Stereo’ and ‘MonoSum L+R’. With a system using a stereo two way configuration and having channels 1 and 3 dedicated for sub-bass operation, it is possible to set these channels either as independent (i.e. in stereo mode) or with the signals from both Left and Right inputs summed. Note: this screen is not available on monitor programs or bi-amp with sub programs.

4) Peak Limiters

OP1+3 Sub

Limiter = +5dBu

Each output has an independent high performance limiter, with both attack and release times fixed and optimally preset according to the frequency range of the channel it operates on. The values (displayed in dBu), refer to signal level at the outputs of the unit.

Follow these steps in order to correctly set limiters for your speaker system:

1.Determine the program power handling of the Turbosound loudspeaker (or HF/LF section as appropriate), or from the engineering data sheet or user manual for that product, or from the label on the rear of the cabinet.

2.Calculate the required limiter voltage using the formula: V = PR

where V is the limiter voltage setting,

and P is the program power rating of the loudspeaker, and R is the nominal impedance of the loudspeaker

LMS-D4 user manual