user manual
MILAN
Troubleshooting
Fault | Check | Action |
|
|
|
No power to the | Is the mains lead plugged in? | Connect the mains lead |
loudspeaker |
|
|
|
|
|
| Is the mains outlet live? | Check the mains outlet or |
|
| switch to another outlet |
|
|
|
| Is the power switch on? | Press the mains switch |
|
|
|
No sound / quiet sound | Is the level control turned | Turn the control slowly |
| down | clockwise |
|
|
|
| Is the source sending a signal? | Verify signal at the source |
|
| output. |
|
| outputs or mixer channels. |
|
| Check cables and/or replace |
|
|
|
| Is the mic/line switch set | Change mic/line setting to |
| incorrectly? | correct source |
|
|
|
No sound from | Is the microphone a | Milan does not supply +48v |
connected microphone | condenser type needing | phantom power. Use a |
| phantom power? | dynamic microphone or |
|
| connect to a mixer with |
|
| phantom power |
|
|
|
No sound although | Is the loudspeaker in protect | Turn off the mains switch, |
loudspeaker is on | mode? | unplug the loudspeaker before |
|
| reconnecting |
|
|
|
| Does the loudspeaker remain | Refer to qualified service |
| in protect mode? | personnel |
|
|
|
Distorted sound | Is the input signal level too | Reduce mixer or preamp level |
| high? |
|
| Is the mic/line switch set | Change mic/line setting to |
| incorrectly? | correct source |
|
|
|
Distorted sound, limit | Are the volume controls set | Reduce volume controls or |
LED is on continuously | too high? | use additional loudspeakers |
|
|
|
Hum or noise | Are the connected sources | Use balanced cables and 3- |
| balanced? | pole connectors wherever |
|
| possible. Check wiring. |
|
|
|
| Ground loops? | Lift audio ground on affected |
|
| device with adapter |
|
|
|
| Are signal cables near or | Move signal cables |
| running parallel to mains |
|
| cables? |
|
|
|
|
MILAN user manual Page 21