Tyco 1529L manual PASS-THRU Command SET LD9100-PT, LD9100X-PT

Models: 1529L

1 169
Download 169 pages 34.79 Kb
Page 156
Image 156

PASS-THRU COMMAND SET (LD9100-PT, LD9100X-PT):

All software commands of the non-pass-thru single sided model are available with following additional commands for pass-thru and double-sided display control. When power is turned on or after a reset command has been initiated, all text is displayed on the pole display.

Extended Pass-thru Command Set is available as option.

Standard Pass-thru Command Set

1.Data to Peripheral <01>, (01), <^A>:

All data following this command will be sent to the peripheral until a “Data to Display” command is received.

2.Data to Display <21><23><02>, (33)(35)(02), {!}{#}{^B}:

All data following this command will be sent to the pole display until a “Data to Peripheral” command is received.

Extended Pass-thru Command Set

1.Data to Peripheral <01><1C><1D><1E>, (01)(28)(29)(30):

All data following this command will be sent to the peripheral until a “Data to Display” command is received.

2.Data to Display <17><18><19><02>, (23)(24)(25)(02):

All data following this command will be sent to the pole display until a “Data to Peripheral” command is received.