Tyco ECM manual Serial Reader/Device Compatibility on an IP System, RS485 Network Compatibility

Models: ECM

1 2
Download 2 pages 21.79 Kb
Page 2
Image 2

CEM/B/052

Product Highlights

Serial Reader/Device Compatibility on an IP System

The ECM improves communications by enabling traditional serial card readers/devices to be quickly and easily connected to an IP-based Ethernet network. A board only option is available to connect into a NCN device in an existing CEM legacy system.

RS485 Network Compatibility

A single ECM can be connected to a chain of up to 16 RS485 readers and multi-dropped up to a distance of 1.2KM.

System Compatibility

The ECM can be used with the AC2000 SE (Standard Edition) or the AC2000 Lite access control systems.

Packaging Options

The ECM is supplied as a standalone boxed unit. A board only option is available to connect into a NCN device in an existing CEM Legacy System.

Windows Configuration

The ECM makes use of a Tibbo Ethernet module for connection to the Ethernet network. Tibbo supply a simple Device Server Toolkit (DST) application for setup and network configuration. Sample configuration files for standalone and legacy (ENCN) modes of operation are supplied.

TECHNICAL SPECIFICATIONS

Physical

 

Communication Interface

Size

140 x 110 x 35mm (5.5 x 4.3 x 1.4”)

To Host

10/100 Base-T TCP/IP using CAT5/6

Weight

0.2Kg

 

Unshielded twisted pair Cable

Housing

Plastic enclosure or PCB only

Connection

RJ45

Housing colour

Beige

 

 

Power

 

To RS485 Card Reader

RS485 multidrop cable runs using using

- Voltage

12Vdc

 

Belden 8723 with maximum length of

- Current

250mA (excluding reader)

 

1.2km without repeater

Consumption

 

Connection

2 part screw terminal

Environmental

 

Product Codes

 

Temperature

-10°C to 55°C

 

 

 

ECM/200/000

ECM (Complete with PSU and Enclosure)

LED Indicators

+12 Volts Power

ECM/200/B04

ECM Board Only Module

 

RS485 Rx and Tx

 

(For use in CEM legacy Systems)

Tibbo LED Indicators

Ethernet 100BaseT

 

 

 

Ethernet Link

 

 

 

Status Red

 

 

 

Status Green

 

 

Functionality

 

 

 

Inputs

10/100MB Ethernet via RJ45 connector

 

 

Outputs

RS232 via DB9 connector

 

 

 

RS485 via 2 part screw terminal

 

 

Reader Power Output

12V, limited to 750mA (MAX) to power a

 

 

 

single CEM reader. Excludes lock power

 

 

Configuration

Configurable via Device Server Toolkit,

 

 

 

telnet or serial connection

 

 

Product specifications and availability is subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of their companies.

CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland

www.cemsys.com

Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: cem.sales@tycoint.com

Page 2
Image 2
Tyco ECM manual Serial Reader/Device Compatibility on an IP System, RS485 Network Compatibility, System Compatibility