NSSD | Tyler Refrigeration |
INSTALLATION PROCEDURES
Carpentry Procedures
Case
NOTE
The NSSD cases are shipped on casters that are replaced with adjustable legs during case
See the
Case
All NSSD models have four
See
Electrical Procedures
Electrical Considerations
CAUTION
Make sure all electrical connections at com- ponents and terminal blocks are tight. This prevents burning of electrical terminals and/or premature component failure.
NOTE
The NSSD has two raceway locations that can house the electrical wiring, components and terminal blocks. All components and wiring can be located in either the lower front or the lower rear of the case.
Case Fan Circuit
This circuit is to be supplied by an uninterrupt- ed, protected 120V circuit. The case fan circuit is not cycled, except when equipped for gas defrost. On gas defrost cases the fan circuit is controlled by a 50/40 klixon.
NOTE
With gas defrost, the fans will not start until the coil temperature reaches 40°F at the fan delay thermostat.
Fluorescent Lamp Circuit
Case lighting is supplied by
NSSD cases have three
Page 6 | March, 2002 |