U-Line 2175BEVOL2 manual Electrical Specifications, Installation Tip, Leveling Information

Models: 2175BEVOL2

1 17
Download 17 pages 37.56 Kb
Page 14
Image 14

2175BEVS/2175BEVOL2 Beverage Center

6 Prepare Power Supply

should be placed along top edge and side edge as shown (see Figure 25).

Electrical Specifications

CAUTION

Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three- prong), polarized receptacle that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC,

60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes.

See Figure 24 for recommended receptacle location.

23-1/4"

7"

1-1/2"

Figure 24

WARNING

SHOCK HAZARD — Electrical Grounding Required.

Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.

Never use an extension cord to connect power to the unit.

Go on to 7 Level the Unit.

 

1

Figure 25

ULIN_0833_A

 

2.If the Beverage Center® is not level, adjust the feet on the corners of the unit as necessary (see Figure 26).

Turn Foot to Adjust

Figure 26

3.Check the levelness after each adjustment and repeat the previous steps until the unit is level. Go on to

8 Install the Unit.

Installation Tip

If the room floor is higher than the floor in the cut-out opening, adjust the rear feet to achieve a total unit rear height of 1/8" less than the opening’s rear height. Shorten the unit height in the front by adjusting the front feet. This allows the unit to be gently tipped into the opening. Readjust the front feet to level the unit after it is correctly positioned in the opening.

7 Level the Unit

Leveling Information

Note: It is recommended that the unit is level.

1.Use a level to check the levelness of the Beverage Center from front to back and from side to side. Level

8 Install the Unit

ANTI-TIP BRACKET INSTALLATION

1.Locate the two Anti-Tip brackets included inside the unit.

www.U-LineService.com

14

03/2008

Page 14
Image 14
U-Line 2175BEVOL2 manual Electrical Specifications, Installation Tip, Leveling Information