Condenser Cleaning

Condenser Cleaning

Interval - Every Three Months

To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.

Interval - Every Three MonthsWARNING

Disconnect electric power to the unit before cleaning the condenser.

Disconnect electric power to the unit before cleaning the condenser.WARNING

DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.

IMPORTANT

DO NOT use any type of cleaner on the condenser unit.

1. Disconnect power to the unit.

ULIN_0228_A

Figure 5

2.Remove the control knob (Figure 5, 1) by pulling it straight out, away from grille.

3.Remove screw from grille (Figure 5, 2) and save.

4.Remove the grille.

1

ULIN_0153_A

Figure 6

5.Clean the condenser coil (Figure 6, 1) using a using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.

1

2

ULIN_0154_A

Figure 7

6.Place the two hook-hinges (Figure 7, 1) located on the rear bottom side of the grille onto the front lip of the unit base. Swing the grille up into position, and align the screw hole on the grille to the grille screw hole on the cabinet.

7.Insert the screw (Figure 5, 2). Do not overtighten.

8.Reinstall the control knob (Figure 5, 1).

9.Reconnect power to the unit.

Leveling

It is important that units equipped with adjustable feet are level, for proper door and ice maker (if equipped) operation.

To level units with adjustable feet:

1

ULIN_0041_A

Figure 8

1.Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown (Figure 8).

1

ULIN_0042_A

Figure 9