Troubleshooting Guide
DANGER
ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on the unit until the main electrical power has been disconnected.
Troubleshooting - What to check when problems occur:
PROBLEM | POSSIBLE CAUSE | REMEDY |
|
|
|
Unit not cold enough | Door gasket not sealing properly | Adjust door (See MAINTENANCE; DOOR ALIGN, ADJUST, |
|
| REVERSE). |
|
|
|
| Item(s) interfering with door | Reposition or remove item(s). |
|
|
|
| Dirty condenser coils | Clean condenser (See MAINTENANCE; CONDENSER |
|
| CLEANING). |
|
|
|
| Airflow to front grille blocked | Airflow must not be obstructed to front grille (See |
|
| OPERATION). |
|
|
|
| Temperature not set cold enough | Set control knob to cooler setting (See OPERATION). |
|
| Allow 24 hours for temperature to stabilize. |
|
|
|
The unit frosts up. | Unit is manual defrost model. | Models SP18, 95, 98, CO29, CO75 and 75F are manual |
|
| defrost (See MAINTENANCE; DEFROSTING). |
|
|
|
| Door gasket not sealing properly | Adjust door (See MAINTENANCE; DOOR ALIGN, ADJUST, |
|
| REVERSE). |
|
|
|
| High ambient temperatures or | Defrost unit manually (See MAINTENANCE; |
| humidity | DEFROSTING). |
|
|
|
Noise during operation | Certain sounds are normal. | Soft sounds from the fan will be heard. |
|
|
|
| Fan blade touching obstruction | Remove obstruction. |
| (wiring, foam insulation, etc.) |
|
|
|
|
75F | 13 |