U-Line 75BEV, 75R, 75WC manual Checking Door Alignment, Electrical Specifications, Adjust Door

Models: 75WC 75BEV 75R

1 13
Download 13 pages 23.46 Kb
Page 10
Image 10
5 Adjust Door

75R, 75WC and 75BEV Models

5 Adjust Door

Checking Door Alignment

The unit’s door is aligned at the factory before shipment. However, its alignment could have been disturbed during shipment or during door panel installation.

IMPORTANT

Properly aligned, the door's gasket should be firmly in contact with the cabinet all the way around the door (no gaps).

1.Carefully examine the door's gasket to assure that it is firmly in contact with the cabinet.

Note: When inspecting door alignment, make sure the light switch bracket makes contact with the light switch plunger. Also make sure the door gasket is not pinched on the hinge side of the door.

2.If the door is properly aligned, go on to 6 Prepare Power Supply. If it is not, use the following procedure.

Adjusting Door Alignment

75R, 75WC and 75BEV Units

1.

Loosen (do not remove)

 

 

top and bottom hinge

 

 

screws. See Figure 17.

 

2.

Align door squarely with

 

 

cabinet. Make sure gasket

 

 

is firmly in contact with

 

 

cabinet all the way around

 

 

the door (no gaps).

 

3.

Tighten bottom hinge

Figure 17

 

screws.

4.Tighten top hinge screws. Go on to 6 Prepare Power Supply.

6 Prepare Power Supply

Electrical Specifications

Checking Door AlignmentCAUTION

Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three- prong), polarized receptacle that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC,

60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes.

See Figure 18 for recommended receptacle location.

23-7/16"

7"

4"

Figure 18

Adjusting Door AlignmentWARNING

SHOCK HAZARD — Electrical Grounding Required.

Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.

Never use an extension cord to connect power to the unit.

Go on to 7 Level the Unit.

www.U-LineService.com

10

02/2005

Page 10
Image 10
U-Line 75BEV, 75R, 75WC manual Checking Door Alignment, Electrical Specifications, Adjust Door, Prepare Power Supply