U-Line 75BEV, 75R Other Site Requirements, Side-By-Side Installation Instructions, Power Supply

Models: 75WC 75BEV 75R

1 13
Download 13 pages 23.46 Kb
Page 7
Image 7
Stainless 75R Units and All 75WC Units
Figure 11

75R, 75WC and 75BEV Models

Stainless 75R Units and All 75WC Units

Note: The grille should not yet be installed. If it has been installed, remove it for door reversing. See Page 11.

Stainless 75R Refrigerator models and Black and Stainless 75WC Wine Captain models are reversible by moving the hinge hardware to the opposite side (Figure 11) as follows:

1.Remove the bottom hinge (two screws) from door.

2.Remove top hinge (two screws) from door.

3. Remove door.

4. Remove top hinge (four screws for 75R or three screws for 75WC) from

cabinet. Invert and install on bottom, opposite side of cabinet.

5.Remove bottom hinge (four screws for 75R or three screws for 75WC) from cabinet. Invert and install on top, opposite side of cabinet.

6.Attach top hinge to door.

7.Attach botton hinge to door.

8.Adjust door to assure proper seal.

Other Site Requirements

Power Supply

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 10.

Environmental Requirements

The surrounding air temperature must be at least 50°F (10°C) but must not exceed 110°F (40°C). Units may be installed outdoors in a covered area. The unit must not be located near heat-generating equipment or in direct sunlight.

Side-By-Side Installation

Instructions

For a complete refreshment center, install two of the following 75 series units side by side: 75R, 75WC and CO75 Combo Ice Maker/Refrigerator. Note that each Side-By- Side Installation will be different.

Cut-out width for a side-by-side installation is the total of the widths listed under Cut-Out Dimensions in each unit’s Installation Guide.

For example:

Placing a 75R next to another 75 series unit would require a cut-out width of:

24-3/16" + 24-3/16" = 48-3/8"

No trim kit is required. However, 1/4-inch space needs to be maintained between the units to ensure unobstructed door swing.

Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s Electrical Specifications.

Typical Side-By-Side Cut-Out

23-7/16"

34-1/4"

to

35-1/8"

7"

4"

1/4" Space

Between

Appliances

Figure 12

02/2005

7

www.U-LineService.com

Page 7