NOTE
Ice thickness adjustment dial should be turned only one increment at a time. Allow unit to stabilize for 24 hours before making further adjustments.
4.Turn ice thickness adjustment dial clockwise for a thicker ice bridge or counterclockwise for a thinner ice bridge.
5.Reinstall front access panel.
6.Reconnect power.
CARE AND CLEANING
EXTERIOR CLEANING
Periodic cleaning and proper maintenance will ensure efficiency, top performance, and long life. We suggest the following:
Avoid the use of solvent cleaning agents, abrasives and all cleansers that may impart taste to the ice cubes. The exterior may be cleaned with
CONDENSER CLEANING
! WARNING !
Disconnect electric power to the ice maker before cleaning the condenser.
!CAUTION
The condenser fins are SHARP. DO NOT run hands over condenser fins.
The front grille should be kept free of dust and lint to permit free air flow to the condenser (see Figure 30). The condenser coil, located behind the front grille and access panel, should be cleaned three to four times each year. Use a soft brush or vacuum cleaner to remove dirt, lint and other accumulations from the condenser coil. Clean from top to bottom, not side to side. Be careful not to bend the condenser fins.
23