Uniden Bearcat 880 owner manual Preventive Maintenance, Calibrate Standing Wave Ratio SWR

Models: Bearcat 880

1 22
Download 22 pages 50.88 Kb
Page 16
Image 16

the microphone to see the RF output power levels. Release PTT to see incoming signal strengh.

Calibrate Standing Wave Ratio (SWR)

Check and calibrate the SWR to ensure that you are using power effectively.

1.Press S/RF/CAL/SWR until CAL and a vertical status bar display on the LCD screen to indicate you are in Calibration mode. No bar graph status levels display.

2.Press and hold PTT; bar graphs status levels display the current level. While still holding PTT, turn Channel Selector to adjust the levels up or down.

3.Release PTT. Press S/RF/CAL/SWR until the LDC displays SWR and 1.5, 2, and 3.

4.Press PTT to see if the new calibration is between 1.5 and 2. Repeat these steps until the calibration level is between 1.5 and 2.

Preventive Maintenance

Every six months:

1.Check the SWR.

2.Be sure all electrical connections are tight.

3.Inspect antenna coaxial cable for wear or breaks in shielding.

4.Be sure all screws and mounting hardware are tight.

Maintenance

The Bearcat 880 is designed to give you years of trouble-free service. There are no user-serviceable parts inside. Except for the fuse in the DC power cord, no maintenance is required.

To replace a blown fuse:

1.Press ends of the fuse holder together. Twist to open. Carefully separate the two pieces.

2.Remove the fuse and inspect. If blown, replace with the same type fuse.

16

Page 16
Image 16
Uniden Bearcat 880 owner manual Preventive Maintenance, Calibrate Standing Wave Ratio SWR