Uniden MHS550 manual Receiver Items Unit Nominal Limit

Models: MHS550

1 68
Download 68 pages 51.38 Kb
Page 59
Image 59

Specifications (cont.)

Receiver

 

 

 

 

Items

 

Unit

Nominal

Limit

Sensitivity for 12dB SINAD

(MRN)

μV

0.3

0.4 max

 

(FRS)

μV

0.35

0.5 max.

 

(FM Broadcast)

μV

1.0

3.0 max.

 

(Air)

μV

1.0

30 max.

 

(AM Broadcast)

μV

1.0

2.0 max.

Squelch Sensitivity

Threshold

μV

0.1

0.25 max.

 

Tight

μV

0.7

2.0 max.

CTCSS/DCS Opening SINAD

(FRS)

dB

8

12 max.

Audio Freq. Response 1kHz Ref.

 

dB

6

3 to 7

(MRN) @ 500Hz

 

 

 

 

(MRN) @ 2000Hz

 

dB

-6

-9 to -5

(FRS) @ 500Hz

 

dB

6

3 to 7

(FRS) @ 2000Hz

 

dB

-6

-9 to -5

Adjacent Channel Selectivity

(MRN ±25kHz)

dB

72

60 min.

 

(FRS ±12.5kHz)

dB

40

30 min.

IM Rejection(MRN)

 

dB

63

55 min.

Image and Spurious Rejection

(MRN)

dB

75

50 min.

Conducted Spurious Emission

 

dBm

-65

-57 max.

at the antenna terminal

 

 

 

 

Hum and Noise Ratio

(MRN)

dB

50

35 min.

 

(FRS)

dB

37

32 min

 

(AM Broadcast)

dB

42

32 min.

 

(FM Broadcast)

dB

53

32 min.

 

(Air)

dB

42

32 min.

THD @ Standard Output Power (MRN)

 

%

1.2

10 max.

Audio Output Power @ 10% THD (MRN)

 

W

0.45

0.3 min.

Oscillator Dropout Voltage (MRN)

 

V

2.9

3.8 max.

Current Drain @ No Signal (MRN)

 

mA

72

85 max.

Current Drain @ Maximum Output (MRN)

 

mA

220

250 max.

Uniden MHS550 Radio Owner’s Manual

59

Page 59
Image 59
Uniden MHS550 manual Receiver Items Unit Nominal Limit