![](/images/new-backgrounds/1300619/300619115x1.webp)
If you experience difficulty while in TrunkTracker mode, try the following steps.
Problem | Suggestion | |
|
|
|
Scanner won’t track. | 1. | Missing the Data Frequency. |
| 2. | Change to a Type 1 Scanner setup. |
|
| Review Fleet Map Programming on page 44. |
|
|
|
Scanner won’t stop | 1. | No IDs have been programmed. |
during Scan List | 2. | The IDs you have stored are not active. |
mode. |
|
|
|
|
|
Scanner will not | 1. | Adjust the squelch for Trunking mode - refer to page 29. |
acquire | 2. | Missing the frequency used for the data channel. |
data channel. |
| Check your frequency list. |
|
|
|
Missing replies to | 1. | Change a Type 1 scanner setup. |
conversations. |
| Review Fleet Map Programming on page 44. |
| 2. | Try another Preset Fleet Map or Program your own Fleet |
|
| Map. |
| 3. | Check to see that all of the system’s frequencies have |
|
| been entered. |
|
|
|
Channel Activity | 1. | May be a telephone interconnect call, which are |
Indicators are flashing |
| intentionally blocked by your scanner. |
but no sound is heard. | 2. The ID on your display is not active. | |
|
|
|
Scanner not tracking | 1. | Logical channel numbers (frequencies) for the system are |
an EDACS system |
| not programmed in the correct order. Check frequency |
properly. |
| resources and reprogram. |
| 2. | Not all frequencies for the system are programmed. |
|
| Check frequency resources. |
|
|
|
If you still cannot get satisfactory results while using your scanner or if you want additional information, please see the Uniden contact details in the warranty page at the back of this manual.
If you have internet access, you can visit www.uniden.com.au, www.uniden.co.nz for additional information.