United States Stove 1600M Installation Of Optional Equipment, Installing Domestic Hot Water Coil

Models: 1600M

1 20
Download 20 pages 63.5 Kb
Page 18
Image 18
INSTALLATION OF OPTIONAL EQUIPMENT

INSTALLATION OF OPTIONAL EQUIPMENT

INSTALLING DOMESTIC HOT WATER COIL

1.Remove access panel at rear of enclosure.

2.With a utility knife cut out the section of fiberglass insulation directly behind the access panel.

3.Remove cover plate from rear of firebox.

4.Place one nut on each end of the coil and thread each as far as they will go.

5.Place the coil through the holes from the inside of the firebox and run a washer and nut down each leg on the outside of the stove. Before tightening the nuts down completely, wrap a piece of hi-temp fiberglass rope gasket, provided with the kit, around each threaded leg between the washer and the outside of the firebox. Tighten the nuts down securely to insure an airtight installation. The installation is now ready to be plumbed to your existing domestic hot water system. Choose one of the three methods described in the Hot Water Kit Installation Instructions.

6.Remove knockouts from access panel and attach to furnace enclosure.

7.Have a qualified plumber connect your domestic hot water pipe to the coil with appropriate fittings.

ACCESS

PANEL1

2

3

5

4

REAR WALL OF FIREBOX

DOMESTIC HOT

WATER COIL

1. NUT

TURN INSIDE NUTS UP

TO END OF THREADS

2. WASHER

 

3. GASKET

 

6

18

Page 18
Image 18
United States Stove 1600M manual Installation Of Optional Equipment, Installing Domestic Hot Water Coil