Installation

CLEARANCES

Your Forester stove has been tested and listed for installation in residential, mobile home, and alcove applications in accordance with the clearances given in FIGURES 3-4 and TABLE 1.

NOTE: Distance “D” on the left-hand side of your Forester stove may need to be greater than the minimum required clearance for suitable access to the control panel.

FIGURE 3

SIDEWALL / CORNER

MINIMUM CLEARANCES

PARALLEL

A - Backwall to heater

8.00” / 203mm

 

B - Backwall to flue

1.00” / 25mm

 

C - Sidewall to flue

7.50” / 191mm

CORNER

D - Sidewall to edge of unit

4.00” / 100mm

E - Adjacent wall to unit

2.00” / 50mm

ALCOVE

F - Alcove depth

25.00” / 635mm

 

G - Alcove Hieght

47.00”/ 1194mm

 

Alcove Width

26.50” / 673mm

TABLE 1

MINIMUM CLEARANCES

(inches/mm)

FIGURE 4

MINIMUM ALCOVE CLEARANCES

6

USSC

Page 6
Image 6