ALCOVE INSTALLATION REQUIREMENTS

ALCOVE INSTALLATION REQUIREMENTS

The American Harvest is approved for the standard alcove height of 52 inches, or for a reduced alcove height with a minimum of 19 inches from the top of the stove (clearance for opening top lids). The maximum alcove depth is 48 inches and the listed clearances are a minimum of 6” on the left side, 2” on the right side and 9” to the rear. The 19” clearance is only needed for opening the back lid. If the front lid protrudes out of the opening, a 1” clearance is all that is required.

ALCOVE CLEARANCE RECOMMENDATIONS

2” Min. on Right Side;

6” Min. on Left Side

See statement

above.

52” Min.

ALCOVE-THROUGH THE WALL INSTALLATION REQUIREMENTS

The stove is approved for horizontal exhaust, however, we recommend that the exhaust goes vertically for five feet, or above the eaves of the house. This will help draw smoke out of the stove in the event of a power failure.

Termination Cap

Corner Installation

9” min.

4’ Minimum Wall Thimble

Vertical Pipe

 

2 ft. Horizontal Pipe

Clean-out

 

Tee

 

Wall Thimble

6” min.

12” min.

 

 

 

 

 

Optional

 

 

Direction

Non Combustible

Hearth Pad

Outside Wall Termination

Termination Cap

Type “PL” Vent

10

USSC

Page 10
Image 10
United States Stove 6035 owner manual Alcove Installation Requirements, Alcove-Throughthe Wall Installation Requirements