United States Stove 6035 Installation Configurations, Mobile Home Installation Requirements

Models: 6035

1 28
Download 28 pages 28.83 Kb
Page 9
Image 9
INSTALLATION CONFIGURATIONS

INSTALLATION CONFIGURATIONS

Note: Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to CAN/CSA -B365

The American Harvest Corn/Pellet Stove Model 6035 may be installed as follows:

1)A freestanding unit

2)A built-in heater mounted in an alcove

MOBILE HOME INSTALLATION REQUIREMENTS

IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTION, THE FOLLOWING

REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:

WARNING

DO NOT INSTALL IN SLEEPING ROOM

1)Stove must be permanently bolted to the floor.

2)Stove must have permanent outside air source. (60FAK)

3)Stove must be permanently electrically ground to the steel chassis of the mobile home.

4)All vertical chimney vent must have wall supports every (5) five feet.

5)All exhaust systems must have a spark arrestor.

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/

ROOF MUST BE MAINTAINED.

Check with your local building official as other codes may apply.

PEDESTAL

BOLT

FLOOR

STEEL CHASSIS

ELECTRICALLY

GROUNDED TO CHASSIS

USSC

9

Page 9
Image 9
United States Stove 6035 Installation Configurations, Mobile Home Installation Requirements, Roof Must Be Maintained