INSTALLATION CONFIGURATIONS

The Multifuel Heater Model 6041TP/6041HF may be installed as follows:

1)A freestanding unit

The Multifuel Heater Model 6041I insert may be installed as follows:

1)In a pre-fab firebox (Factory Built)

2)In an existing masonry fireplace

3)As a build-in

MOBILE HOME INSTALLATION REQUIREMENTS

IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTION, THE FOLLOWING

REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:

WARNING

DO NOT INSTALL IN SLEEPING ROOM

1)Heater must be permanently bolted to the floor. Remove the Base Trim and bolt thru the base flange.

2)Heater must have permanent outside air source. (69FAK)

3)Heater must be permanently electrically grounded to the steel chassis of the mobile home.

4)All vertical chimney vent must have wall supports.

5)All exhaust systems must have a spark arrestor.

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/

ROOF MUST BE MAINTAINED.

Check with your local building official as other codes may apply.

12

USSC

Page 12
Image 12
United States Stove 6041TP, 6041I, 6041HF warranty Installation Configurations, Mobile Home Installation Requirements