United States Stove 6041I, 6041HF CLEARANCES TO COMBUSTIBLES 6041TPHF, Back Wall, Side Wall

Models: 6041HF 6041 6041I 6041TP

1 32
Download 32 pages 490 b
Page 8
Image 8
CLEARANCES TO COMBUSTIBLES 6041(TP)(HF)

CLEARANCES TO COMBUSTIBLES 6041(TP)(HF)

The heater must be installed with the following minimum clearances to side and back wall combustible materials.

NOTE: These are minimum clearances to combustible walls established by the testing lab.

PARALLEL - A -

Sidewall to Top Edge of Unit

8 in./203mm

B -

Sidewall to Flue

13 in./330mm

C -

Backwall to Flue

3 in./75mm

D - Backwall to Unit

9 in./228mm

CORNER - E -

Adjacent Wall to Flue

3 in./75mm

F -

Adjacent Wall to Unit

4 in./100mm

 

BACK WALL

BACK WALL

SIDE WALLBACK WALLSIDE WALLManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

SIDE WALL

Backwall / Sidewall

Corner Installation

Parallel

NOTE:

Allow sufficient space to remove the left and right side panels for maintenance purposes.

 

 

6”

 

 

min.

6”

HEARTH PROTECTION

6”

min.

 

min.

These clearances must be maintained.

8

USSC

Page 8
Image 8
United States Stove 6041I, 6041HF warranty CLEARANCES TO COMBUSTIBLES 6041TPHF, Back Wall, Side Wall