CLEARANCES TO COMBUSTIBLES 6041(TP)(HF)
The heater must be installed with the following minimum clearances to side and back wall combustible materials.
NOTE: These are minimum clearances to combustible walls established by the testing lab.
PARALLEL - A - | Sidewall to Top Edge of Unit | 8 in./203mm |
B - | Sidewall to Flue | 13 in./330mm |
C - | Backwall to Flue | 3 in./75mm |
D - Backwall to Unit | 9 in./228mm | |
CORNER - E - | Adjacent Wall to Flue | 3 in./75mm |
F - | Adjacent Wall to Unit | 4 in./100mm |
| BACK WALL | BACK WALL |
SIDE WALL
SIDE WALL
Backwall / Sidewall | Corner Installation |
Parallel |
NOTE:
Allow sufficient space to remove the left and right side panels for maintenance purposes.
|
| 6” |
|
| min. |
6” | HEARTH PROTECTION | 6” |
min. |
| min. |
These clearances must be maintained.
8 | USSC |