United States Stove 6100 Installation Options, Additional Items Needed For Installation

Models: 6100

1 24
Download 24 pages 6.37 Kb
Page 6
Image 6
Installation

Installation

INSTALLATION OPTIONS

Read this entire manual before you install and use your Multi-Fuel Furnace. Failure to follow instructions may result in property damage, bodily injury, or even death!

(See specific installation details for clearances and other installation requirements)

As a Primary Furnace—the unit functions independently of any other system. The “Room Air” blowers will come on when the plenum and Exhaust temperatures reach a preset point on the furnace’s circuit board (PCB). Unit may also be used as a stand-alone shop heater

As a Secondary (Add-On)Furnace—the unit aids an existing gas/electric furnace helping cut down on operation time.

It is recommended that only a authorized technician install your Multi-Fuel Furnace, preferably an NFI certified specialist.

IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the mal- function of a furnace due to improper venting or installation. Call (800) 750-2723 and/or consult a professional installer if you have any questions.

ADDITIONAL ITEMS NEEDED FOR INSTALLATION

UL listed 3 inch or 4 inch (Depending on application) “PL” pellet venting exhaust system.

Air distribution duct work. Transition from 4.5 inch x 18.5 inch rectangle to 10 inch round is provided.

Air filter (Optional). Size: 10 x 20 x 1

Floor Protection (If not installed on a non-combustible floor)

Air return vent from the house to the room where furnace is installed.

Fresh air for combustion if located in a small, tightly constructed room.

FLOOR PROTECTION

This unit must be installed on a non-combustible floor surface. If a floor pad is used, it should be UL listed or equal. The floor pad or non-combustible surface should be large enough to extend a minimum of 6-inches in front, 6-inches on each side, and 1-inch behind the furnace for horizontal termination.

Floor protection must extend under and 2-inches to each side of the chimney tee for an interior vertical termination. A Floor Protector of 1 inch thick is recommended for this installation.

6

USSC

Page 6
Image 6
United States Stove 6100 owner manual Installation Options, Additional Items Needed For Installation, Floor Protection