Heat & Glo LifeStyle PIER-HV-IPI, LCOR-HV-IPI, ST-HV-IPI Wall Switch Installation for Fan Optional

Models: PIER-HV-IPI ST-HV-IPI RCOR-HV-IPI LCOR-HV-IPI

1 45
Download 45 pages 11.12 Kb
Page 39
Image 39
Wall Switch Installation for Fan (Optional)

Wall Switch Installation for Fan (Optional)

If the box is being wired to a wall mounted switch for use with a fan (See Figure 38):

The power supply for the appliance must be brought into a switch box.

The power can then be supplied from the switch box to the appliance using a minimum of 14-3 with ground wire.

At the switch box connect the black (hot) wire and red (switch leg) wire to the wall switch as shown.

At the appliance connect the black (hot), white (neutral) and green (ground) wires to the junction box as shown.

Add a 1/4 inch insulated female connector to the red (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 inch male) as shown.

MINIMUM 14-3 AWG

WITH GROUND

Red

Black

White

Green

JUNCTION BOX

Green

White

Black

Red

SWITCH

Black

White

Green

POWER

SUPPLY WIRES

SWITCH BOX

Red

Figure 38. Junction Box Wired to Wall Switch