Figure 18. Venting with three 90° elbows

 

 

NATURAL GAS

 

 

PROPANE

 

 

 

VENTING WITH THREE 90° ELBOWS

 

VENTING WITH THREE 90° ELBOWS

 

 

V + V1 (FT.)

H + H1 (FT.)

 

V + V1 (FT.)

 

H + H1 (FT.)

 

 

1' MIN. (305mm)

3' MAX. (914mm)

1' MIN. (305mm)

 

2' MAX. (610mm)

 

 

2' MIN. (610mm)

6' MAX.

(1.83m)

2' MIN. (610mm)

 

4' MAX.

(1.22m)

 

 

3' MIN. (914mm)

9' MAX.

(2.7m)

 

3' MIN. (914mm)

 

6’ MAX. (1.83m)

 

 

4' MIN. (1.22m)

12' MAX.

(3.6m)

 

4' MIN. (1.22m)

 

8' MAX.

(2.4m)

 

 

5’ MIN. (1.5m)

15’ MAX.

(4.5m)

 

5’ MIN. (1.5m)

 

10' MAX.

(3.0m)

 

 

6’ MIN. (1.83m)

18’ MAX.

(5.5m)

 

6’ MIN. (1.83m)

 

12' MAX.

(3.6m)

 

 

V+ V1 + H + H1 = 50’ MAX. (15.2m)

 

V+ V1 + H + H

1

= 50’ MAX. (15.2m)

 

 

H + H1 = 18’ MAX. (5.5m)

 

H + H1 = 12’ MAX. (3.6m)

V1

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

H1

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

H2

 

 

 

 

 

 

 

 

 

 

 

 

H1

 

 

 

 

 

 

 

 

 

 

H

 

 

 

NATURAL GAS

 

 

PROPANE

 

 

 

 

VENTING WITH THREE 90° ELBOWS

VENTING WITH THREE 90° ELBOWS

 

 

 

V + V1 (FT.)

H + H1 + H2 (FT.)

V + V1 (FT.)

 

H + H1 + H2 (FT.)

 

 

 

1' MIN. (305mm)

3' MAX. (914mm)

1' MIN. (305mm)

 

2' MAX. (610mm)

 

 

 

2' MIN. (610mm)

6' MAX.

(1.83m)

2' MIN. (610mm)

 

4' MAX.

(1.22m)

 

 

 

3' MIN. (914mm)

9' MAX.

(2.7m)

3' MIN. (914mm)

 

6’ MAX. (1.83m)

 

 

 

4' MIN. (1.22m)

12' MAX.

(3.6m)

4' MIN. (1.22m)

 

8' MAX.

(2.4m)

 

 

 

5’ MIN. (1.5m)

15’ MAX.

(4.5m)

5’ MIN. (1.5m)

 

10' MAX.

(3.0m)

 

 

 

6’ MIN. (1.83m)

18’ MAX.

(5.5m)

6’ MIN. (1.83m)

 

12' MAX.

(3.6m)

 

 

 

V+ V1 + H + H1 + H2 = 50’ MAX. (15.2m)

V+ V1 + H + H1 + H2 = 50’ MAX. (15.2m)

 

 

 

H + H1 + H2 = 18’ MAX. (5.5m)

H + H1 + H2 = 12’ MAX. (3.6m)

 

 

 

Figure 18. Venting with three 90° elbows

 

 

 

 

 

 

 