Heat & Glo LifeStyle ST-HV-IPI, LCOR-HV-IPI, RCOR-HV-IPI, PIER-HV-IPI Venting with One 90 Elbow

Models: PIER-HV-IPI ST-HV-IPI RCOR-HV-IPI LCOR-HV-IPI

1 45
Download 45 pages 11.12 Kb
Page 25
Image 25
Figure 13. Venting with One 90° Elbow

NATURAL GAS - VENTING WITH ONE 90° ELBOW

 

V (FT.)

H (FT.)

 

1' MIN. (305mm)

3' MAX. (914mm)

 

2' MIN. (610mm)

6' MAX.

(1.83m)

 

3' MIN. (914mm)

9' MAX.

(2.7m)

 

4' MIN. (1.22m)

12' MAX.

(3.6m)

 

5’ MIN. (1.5m)

15’ MAX.

(4.5m)

 

6’ MIN. (1.83m)

18’ MAX.

(5.5m)

 

V + H = 50’ MAX. (15.2m)(11.3m)

 

PROPANE - VENTING WITH ONE 90° ELBOW

 

V (FT.)

H (FT.)

 

1' MIN. (305mm)

2' MAX. (610mm)

V

2' MIN. (610mm)

4' MAX.

(1.22m)

 

3' MIN. (914mm)

6’ MAX. (1.83m)

 

4' MIN. (1.22m)

8' MAX.

(2.4m)

 

5’ MIN. (1.5m)

10' MAX.

(3.0m)

 

6’ MIN. (1.83m)

12' MAX.

(3.6m)

 

V + H = 50’ MAX. (15.2m)

 

H

Figure 13. Venting with One 90° Elbow

 

 

 

 

 

H

 

 

 

 

 

 

 

 

V

NATURAL GAS

 

 

PROPANE

 

 

VENTING WITH ONE 90° ELBOW

VENTING WITH ONE 90° ELBOW

 

V (FT.)

H (FT.)

V (FT.)

H (FT.)

 

900 Elbow on top

2.5’ MAX. (64mm)

900 Elbow on top

2’ MAX. (610mm)

 

1' MIN. (305mm)

3' MAX. (914mm)

1' MIN. (305mm)

2' MAX. (610mm)

 

2' MIN. (610mm)

6' MAX.

(1.83m)

2' MIN. (610mm)

4' MAX.

(1.22m)

 

3' MIN. (914mm)

9' MAX.

(2.7m)

3' MIN. (914mm)

6’ MAX. (1.83m)

 

4' MIN. (1.22m)

12' MAX.

(3.6m)

4' MIN. (1.22m)

8' MAX.

(2.4m)

 

5’ MIN. (1.5m)

15’ MAX.

(4.5m)

5’ MIN. (1.5m)

10' MAX.

(3.0m)

 

6’ MIN. (1.83m)

18’ MAX.

(5.5m)

6’ MIN. (1.83m)

12' MAX.

(3.6m)

 

V + H = 50’ MAX. (15.2m)

V + H = 50’ MAX. (15.2m)

 

Figure 14. Venting with One 90° Elbow

 

 

 

 

 

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI2005-900 Rev. K • 11/06

25

Page 25
Image 25