Image 38
Figure 35. Fan Wiring Diagram

TEMPERATURE

SENSOR SWITCH

SPEED CONTROL

(RHEOSTAT)

Figure 35. Fan Wiring Diagram

NOTE: If any of the original wire as supplied with the appliance must be replaced, it must be replaced with the type 105oC rated wire.

FAN JUNCTION

BOX

 

DETAIL A

SEE DETAIL A

SCALE 1/1

 

Optional Accessories

Optional fan and remote control kits require that 110-120 VAC be wired to the factory installed junction box before the fireplace is permanently installed.

Fan Installation

Recommended fan locations for the type of fireplace you have (see Figures 36 and 37).

Wall Switch

Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/OFF switch pigtails.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPERAND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

FAN

Figure 36. Corner fan location

Corner fan location

It is recommended to position the fan in this location as shown. This will provide the best air flow (see Figure 36).

FAN

Figure 37. ST & PIER fan location

ST & Pier fan location

It is recommended to position the fan on the same side of the fireplace as the vent collars are on. This will provide the best air flow (see Figure 37).

38

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI2005-900 Rev. K • 11/06

Page 38
Image 38