Heat & Glo LifeStyle LCOR-HV-IPI, ST-HV-IPI, RCOR-HV-IPI, PIER-HV-IPI Flue Restrictor Instructions

Models: PIER-HV-IPI ST-HV-IPI RCOR-HV-IPI LCOR-HV-IPI

1 45
Download 45 pages 11.12 Kb
Page 24
Image 24
Flue Restrictor Instructions

STRAIGHT UP

 

VERTICAL VENTING

 

V (FT.)

 

50' MAX. (15.2 M)

CAP

NOTE: On vertical venting configurations you may want to install the flue re-

BREAK

HERE

Figure 10. Flue Restrictor

strictor (385-128). See flue restrictor installation in- structions.

Figure 8

4.Match the amount of vertical in the system with the chart to find the appropriate position to set the Flue Restrictor.

- CHART -

Vertical

Settings

4'

1-1

8'

1-2

15'

2-2

20'

2-3

25'

3-3

30'

4-3

35'

4-4

40'

4-4

50'

4-5

Flue Restrictor Instructions

1.Locate the Flue Restrictor which is in the manual bag.

FLUE

RESTRICTOR

Figure 9

2.Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 10).

5. Center the Flue Restrictor on vent and secure in place using two self-tapping screws (see Figure 11).

 

1

2

3

4

5

 

 

 

 

 

SETTINGS

Figure 11

1

2

3

4

5

 

 

 

 

 

STRAIGHT OUT

 

 

 

 

 

HORIZONTAL VENTING

 

 

 

 

 

H

 

 

 

 

 

Max. Run

 

 

 

 

 

24" (610 mm)

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

Figure 12.

24

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI2005-900 Rev. K • 11/06