LOWER “HALL EFFECT” SENSOR (OPTIONAL)

Some L60 tamp label applicators are equipped with two sensors that are attached to the air cylinder. One is located at the top of the cylinder and the other is located below it. The upper sensor sends a signal to the machine so another label will be dispensed onto the vacuum head. The lower sensor can be adjusted to control or limit the stroke of the air cylinder that returns the vacuum head to the home position. The lower sensor is the only one that may require adjustment.

Fig 10

Hall effect

Hall effect

sensors.

connections.

 

 

 

 

 

 

Fig 11

Adjusting the Lower “Hall Effect” Sensor:

1.With Main switch “On” and Motor switch “Off”.

2.Disconnect air supply or turn tamp regulator “Off”.

3.Bring Tamp Head down to new product height.

4.Loosen Phillips screw on Hall Effect Sensor.

5.Slide sensor to top of cylinder, then down until the indicator light on the sensor lights up.

6.Tighten the Phillips screw on the sensor.

Page 13

Page 13
Image 13
Universal L60 manual Lower Hall Effect Sensor Optional, Adjusting the Lower Hall Effect Sensor