OPERATING INSTRUCTIONS

START

WARNING: When lighting the heater DO NOT look over top of heater (reflector). Stand to the side of the heater during ignition. Do not stand or have any part of your body in front of the heater.

1.WARNING: MAKESURETHEREISNOOPENFLAMEINTHE AREA. Fully open the valve on the propane cylinder.

2.Turn the heater regulator knob counterclockwise to the "HI"

position.

3.To light: (Read all lighting instructions before attempting to ignite heater)

a)Repeatedly push and release the piezo electric ignitor (SPC-30R), or place a lighted match near the face of the heating element (mesh screen) of the burner you are lighting, using the hole located on the side of the reflector. CAUTION: DO NOT LIGHT AT THE ORIFICE.

b)Depress the red button on the safety valve admitting gas to the burner. WARNING: DO NOT DEPRESS RED

VALVE BUTTONBEFOREREPEATEDLYACTIVATING THEPIEZO(SPC-30R)ORINSERTINGMATCH.

c)When the gas on the face of the mesh screen lights, continue to hold the valve button depressed for 30

seconds, then release.

4.If flame goes out, wait 5 minutes and repeat the lighting procedure.

5.If heater will not light after repeated tries, do not attempt to repair heater. Return heater to nearest authorized service center or to manufacturer of this product, freight prepaid.

6.(SPC-30R) Repeat steps 1 through 4 to ignite the other burner.

7.After both burners (SPC-30R) or single burner (SPC-15R), are lit, turn the heater regulator knob to the desired heat setting (LOW, MED, HI).

MAINTENANCEANDSTORAGE

1.The heater should be inspected before each use, and at least annually by a qualified person.

2.Before each use, check the soft "O" ring seat at the bullnose of the POL fitting. If the "O" ring is cut, scuffed, or otherwise damaged, replace it with part number 6681.

3.Turn off the gas at the LP-gas supply cylinder when the heater is not in use.

4.When the heater is to be stored, the connection between the LP-gas supply cylinder and the heater must be disconnected and the cylinder removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58.

SERVICING

A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:

*The flame is contained within the heater.

*The flame is essentially blue.

*There is no strong disagreeable odor, eye burning or other physical discomfort.

*There is no smoke or soot internal or external to the heater.

*There are no unplanned or unexplained shut downs of the heater.

The parts lists and exploded view show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. IMPORTANT For this heater, the regulator must be set as shown in "specifications". If there is any uncertainty about the regulator setting, have it checked.

STOP

1.Securely close valve on the propane cylinder.

2.Turn the heater regulator knob to the "OFF" position. Wait 15 minutes for the heater to cool down before handling heater.

3.Always remove the heater from the propane tank after each use. Do not store the heater while attached to propane tank. Remove the heater from the propane tank by turning the fuel connector nut clockwise. Always store propane tank outdoors. Never store propane tank in an enclosed area.

RESTARTAFTERSAFETYSHUTDOWN

1.Securely close valve at propane cylinder.

2.Wait 5 minutes.

3.Restart following "Start" procedure.

A heater which is not working right must be repaired, but only by a trained, experienced service person. To find the service center closest to you, visit our website at www.scheuco.com.or call (888) 619-7060.

You may also obtain in-warranty or out-of-warranty service by taking the product to your local service center.

In-warranty products will be repaired with no charge for either parts or labor. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.

Out-of-warrranty products will be repaired with a charge for parts and labor.