Models

SPC-15R/15R SPC-30R/30R

OPERATING INSTRUCTIONS

START

WARNING: When lighting the heater DO NOT look over top of heater (reflector). Stand to the side of the heater during ignition. Do not stand or have any part of your body in front of the heater.

1.WARNING: MAKESURETHEREISNOOPENFLAMEINTHE AREA. Fully open the valve on the propane cylinder.

2.Turn the heater regulator knob counterclockwise to the "HI"

position.

3.To light: (Read all lighting instructions before attempting to ignite heater)

a)Repeatedly push and release the piezo electric ignitor (SPC-30R), or place a lighted match near the face of the heating element (mesh screen) of the burner you are lighting, using the hole located on the side of the reflector. CAUTION: DO NOT LIGHT AT THE ORIFICE.

b)Depress the red button on the safety valve admitting gas to the burner. WARNING: DO NOT DEPRESS RED

VALVE BUTTONBEFOREREPEATEDLYACTIVATING THEPIEZO(SPC-30R)ORINSERTINGMATCH.

c)When the gas on the face of the mesh screen lights, continue to hold the valve button depressed for 30

seconds, then release.

4.If flame goes out, wait 5 minutes and repeat the lighting procedure.

5.If heater will not light after repeated tries, do not attempt to repair heater. Return heater to nearest authorized service center or to manufacturer of this product, freight prepaid.

6.(SPC-30R) Repeat steps 1 through 4 to ignite the other burner.

7.After both burners (SPC-30R) or single burner (SPC-15R), are lit, turn the heater regulator knob to the desired heat setting (LOW, MED, HI).

MAINTENANCEANDSTORAGE

1.The heater should be inspected before each use, and at least annually by a qualified person.

2.Before each use, check the soft "O" ring seat at the bullnose of the POL fitting. If the "O" ring is cut, scuffed, or otherwise damaged, replace it with part number 6681.

3.Turn off the gas at the LP-gas supply cylinder when the heater is not in use.

4.When the heater is to be stored, the connection between the LP-gas supply cylinder and the heater must be disconnected and the cylinder removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58.

SERVICING

A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:

*The flame is contained within the heater.

*The flame is essentially blue.

*There is no strong disagreeable odor, eye burning or other physical discomfort.

*There is no smoke or soot internal or external to the heater.

*There are no unplanned or unexplained shut downs of the heater.

The parts lists and exploded view show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. IMPORTANT For this heater, the regulator must be set as shown in "specifications". If there is any uncertainty about the regulator setting, have it checked.

STOP

1.Securely close valve on the propane cylinder.

2.Turn the heater regulator knob to the "OFF" position. Wait 15 minutes for the heater to cool down before handling heater.

3.Always remove the heater from the propane tank after each use. Do not store the heater while attached to propane tank. Remove the heater from the propane tank by turning the fuel connector nut clockwise. Always store propane tank outdoors. Never store propane tank in an enclosed area.

RESTARTAFTERSAFETYSHUTDOWN

1.Securely close valve at propane cylinder.

2.Wait 5 minutes.

3.Restart following "Start" procedure.

A heater which is not working right must be repaired, but only by a trained, experienced service person. To find the service center closest to you, visit our website at www.scheuco.com.or call (888) 619-7060.

You may also obtain in-warranty or out-of-warranty service by taking the product to your local service center.

In-warranty products will be repaired with no charge for either parts or labor. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.

Out-of-warrranty products will be repaired with a charge for parts and labor.

Page -8-

Page 8
Image 8
Universal SPC-30R/30R, SPC-15R/15R owner manual Operating Instructions, Servicing

SPC-15R/15R, SPC-30R/30R specifications

The Universal SPC-30R/30R and SPC-15R/15R are versatile, high-performance devices widely used in various industries for monitoring and controlling processes. These machines are integral to modern manufacturing and production environments, offering advanced features that enhance productivity, precision, and efficiency.

One of the standout features of the Universal SPC models is their robust data collection and analysis capabilities. They come equipped with state-of-the-art sensors that provide real-time monitoring of critical parameters, ensuring that any deviations from desired specifications are detected immediately. This real-time data access not only facilitates immediate corrective actions but also aids in maintaining consistent product quality.

The SPC-30R/30R models boast enhanced connectivity options, allowing seamless integration with existing systems. This connectivity ensures that data can be shared effortlessly across different platforms, enabling comprehensive process optimization. Furthermore, the use of advanced wireless technology in these models means that operators can access performance data remotely, enhancing overall operational flexibility.

Another key characteristic of the Universal SPC series is their user-friendly interface. Designed with an intuitive layout, the controls and display screens are easily navigable, making it simple for operators to monitor processes and manage settings. This ease of use minimizes training time and helps reduce the likelihood of operator error.

In terms of technology, the SPC-30R/30R and SPC-15R/15R are equipped with sophisticated algorithms that analyze the collected data and provide actionable insights. This predictive analytics capability not only improves decision-making processes but also allows for proactive maintenance schedules, thus reducing downtime and extending the lifespan of equipment.

The durability of these models is yet another advantage. Built with high-quality materials and designed to operate in demanding conditions, the Universal SPC devices are less prone to failure, ensuring reliable performance even in harsh environments. Their compact form factor also allows for easy installation in various settings, maximizing space utilization.

Moreover, the versatility of the Universal SPC series extends beyond single-function applications. They can be employed in diverse fields such as automotive, aerospace, pharmaceuticals, and consumer goods manufacturing. This adaptability makes them a valuable investment for any organization looking to enhance its operational capabilities.

In summary, the Universal SPC-30R/30R and SPC-15R/15R are exemplary devices that combine advanced features, intuitive technology, and reliable performance. Their robust capabilities make them essential tools for organizations aiming to optimize productivity, ensure quality, and maintain efficiency in today's competitive industrial landscape.