FREESTANDING FIREPLACE ASSEMBLY
Continued
INSTALLING REAR COVER
1.Lift rear panel over vent pipe connec- tion on firebox. Rear cover will rest on the bottom ledge of the stove body.
2.Using screws provided, attach rear cover to back of stove body. See Figure 17.
IMPORTANT: This rear cover must be securely in place before venting pipes are installed.
VENTING INSTALLATION
WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage, or loss of life. Operation of im- properly installed and maintained venting system could result in serious injury, property damage, or loss of life.
NOTICE: Failure to follow these instructions will void the warranty.
INSTALLATION PRECAUTIONS
Consult local building codes before begin- ning the installation. Only a qualified ser- vice person should install venting system. The installer must follow these safety rules:
•Wear gloves and safety glasses for protection
•Use extreme caution when using ladders or when on roof tops
•Be aware of electrical wiring locations in walls and ceilings
The following actions will void the war- ranty on your venting system:
• | Installation of any damaged venting |
| component |
• Unauthorized modification of the vent- | |
| ing system |
• | Installation of any component part not |
Rear
Cover
Screw
Firebox
Installed In Cast
Iron Stove Body
Figure 17 - Installing Rear Cover
manufactured or approved by DESA |
International |
• Installation other than as instructed by |
these instructions |
Your fireplace is approved for use with any listed gas vent. A listed gas vent is a factory made and listed system designed, and in- stalled exclusively for removing products of combustion, excess air, and dilution air resulting from burning fuel gas. Metal vents, the most common type of vent, employ double wall construction enclosing an insu- lating air space. This air space both helps keep flue gases warm and reduce heat trans- ferred to nearby combustibles. This appli- ance is equipped with a safety control sys- tem designed to protect against improper venting of combustion products.
It is very important that the venting system maintain its balance between the combus- tion air intake and the flue gas exhaust. Certain limitations apply to vent configura- tions and must be strictly followed.
WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance.