Extension Cord

OWNER’S MANUAL

INSTALLATION

Continued

Extension Cord

Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

Attaching Wood Base to Solid Floor

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware pack- age is provided with fireplace.

1.

Drill holes at marked locations using

 

5/16" drill bit. For solid floors (concrete

 

or masonry), drill at least 1" deep.

2.

Fold floor anchor as shown in Figure 21.

3.

Insert floor anchor (wings first) into

 

hole. Tap anchor flush to floor.

4.

Insert mounting screws through base

 

and into floor anchors.

5.

Tighten screws until base is firmly fas-

CONNECTING TO GAS SUPPLY

Attaching Wood Base to Solid Floor WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes.

CONNECTING TO GAS SUPPLY WARNING: Never connect fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

IMPORTANT: Check gas line pressure be- fore connecting fireplace to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, fireplace regulator damage could occur.

Manual backgroundCAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" or greater diam- eter to allow proper gas volume to fireplace. If pipe is too small, un- due loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 22).

IMPORTANT: Install main gas valve (manual shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

Manual backgroundCAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 22. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

tened to floor.

 

A.G.A. Design-Certified Manual

From Gas Meter

Shutoff Valve with 1/8" NPT Tap*

 

(5" W.C.** to

Approved Flexible

10.5" W.C.

Gas Hose

Pressure)

 

Gas Control

Figure 21 - Folding Anchor

 

Tee Joint

 

Pipe

 

Nipple

3" Minimum

Cap

Sediment Trap

Figure 22 - Gas Connection

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, pages 26 and 27.

**Minimum inlet pressure for purpose of input adjustment.

Continued

104325

13