® VMH26NR

COMPACT CLASSIC HEARTH FIREPLACE

AIR FOR

COMBUSTION AND

VENTILATION

Continued

DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = _______________ cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free fireplace

 

____________ Btu/Hr

 

 

 

 

Gas water heater*

 

____________ Btu/Hr

Example:

 

 

 

Gas furnace

 

____________ Btu/Hr

Gas water heater

 

30,000

Btu/Hr

Vented gas heater

 

____________ Btu/Hr

Vent-free fireplace

+

26,000

Btu/Hr

Gas fireplace logs

 

____________ Btu/Hr

Total

=

56,000

Btu/Hr

Other gas appliances*

+

____________ Btu/Hr

 

 

 

 

Total

=

____________ Btu/Hr

 

 

 

 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_________________ Btu/Hr (maximum the space can support)

_________________ Btu/Hr (actual amount of Btu/Hr used)

Example: 51,200 Btu/Hr (maximum the space can support) 56,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7.

C.Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3 or applicable local codes.

6

104325

Page 6
Image 6
Vanguard Heating VMH26NR AIR for Combustion Ventilation, Determining FRESH-AIR Flow for Fireplace Location

VMH26NR specifications

The Vanguard Heating VMH26NR is an innovative heating solution designed to provide efficient warmth while prioritizing energy savings and user comfort. With its sleek design and advanced technologies, the VMH26NR stands out in the crowded market of heating appliances.

One of the main features of the VMH26NR is its powerful heating capability. Equipped with a robust heating element, it can produce a significant amount of warmth quickly, making it ideal for medium to large spaces. Whether you are heating a living room, office, or workshop, the VMH26NR ensures that you stay comfortable during the colder months.

Efficiency is another hallmark of this model. The VMH26NR employs cutting-edge energy-saving technologies that optimize power consumption. This not only reduces energy bills but also lessens the environmental impact associated with conventional heating methods. Users can enjoy a warm atmosphere while being conscious of their carbon footprint.

The VMH26NR also features a user-friendly digital thermostat, which allows for precise temperature control. Users can easily adjust the settings to their comfort level, ensuring that the space remains at an ideal temperature without unnecessary energy expenditure. The digital display provides clear readings, making it easy to monitor performance and settings.

For added convenience, the unit comes with a programmable timer, allowing users to schedule the heating periods according to their routines. This feature is particularly beneficial for those who want the heater to operate only when needed, further enhancing energy efficiency and user convenience.

Safety is a top priority in the design of the VMH26NR. It is equipped with several safety features, including overheat protection and a tip-over switch, which automatically shuts off the unit in case of accidents. This ensures peace of mind, especially in households with pets or young children.

The Vanguard Heating VMH26NR also boasts a compact, portable design that makes it easy to move from room to room. Its lightweight construction and built-in handles provide added portability, allowing users to enjoy warmth wherever it is needed most.

In conclusion, the Vanguard Heating VMH26NR is a powerful, efficient, and user-friendly heating solution. Its advanced features, safety mechanisms, and adaptability make it an excellent choice for anyone looking to enhance their comfort during the chilly seasons. Whether you are a homeowner or a business owner, the VMH26NR promises to deliver reliable performance and satisfaction.