Vanguard Heating VMH26NR Connecting Fireplace To Gas Supply, Installation Items Needed, Continued

Models: VMH26NR

1 30
Download 30 pages 50.24 Kb
Page 14
Image 14
CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items NeededManual backgroundManual backgroundManual backgroundManual background ® VMH26NR

COMPACT CLASSIC HEARTH FIREPLACE

INSTALLATION

Continued

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove screws that attach branch sup- port to fireplace (see Figure 23). Care- fully lift up branch support and remove from fireplace (see Figure 23).

3.Route flexible gas line (provided by installer) from manual shutoff valve into fireplace through side or rear ac- cess holes in outer casing. Route flex- ible gas supply line through fireplace access holes in outer casing.

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 24). The flexible gas supply line con- nection to the manual shutoff valve should be accessible.

4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line (see Figure 24). Con- nect flexible gas line to flexible gas line attached to gas valve of fireplace (see Figure 24).

5.Check all gas connections for leaks. See Checking Gas Connections, page 15.

6.Replace branch support back into fire- place. Feed flexible gas line into fire- place base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reat- tach branch support to fireplace with screws removed in step 2.

Screen

Shipping

Screw

Shoulder

Screw

Screen

Branch

Support

Figure 23 - Removing Branch Support From Fireplace

To Fireplace

Gas

Valve

Manual Shutoff Valve

Gas Connector

 

 

 

Flexible Gas Line from

Flexible Gas Line from

Fireplace Gas Valve

Manual Shutoff Valve

Provided with Fireplace

Provided by Installer

 

 

To Gas

Supply

Figure 24 - Attaching Flexible Gas Lines Together

14

104325

Page 14
Image 14
Vanguard Heating VMH26NR installation manual Connecting Fireplace To Gas Supply, Installation Items Needed, Continued