® VMH26TPA

COMPACT CLASSIC HEARTH FIREPLACE

INSTALLATION

Continued

Attaching Wood Base to Solid Floor

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware pack- age is provided with fireplace.

1.Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep.

2.Fold floor anchor as shown in Figure 21.

3.Insert floor anchor (wings first) into hole. Tap anchor flush to floor.

4.Insert mounting screws through base and into floor anchors.

5.Tighten screws until base is firmly fas- tened to floor.

Figure 21 - Folding Anchor

CONNECTING TO GAS

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" or greater diameter to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.

External Regulator

Propane/LP

Supply Tank

Vent Pointing Down

Figure 22 - External Regulator with Vent Pointing Down

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 23).

IMPORTANT: Install main gas valve (manual shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 23. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

SUPPLY

WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes.

Approved Flexible

Gas LineA.G.A. Design-Certified Manual

Shutoff Valve With 1/8" NPT Tap*

CAUTION: Never connect fire- place directly to the propane/LP supply. This fireplace requires an external regulator (not sup- plied). Install the external regula- tor between the fireplace and pro- pane/LP supply.

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regu- lator with the vent pointing down as shown in Figure 22. Pointing the vent down pro- tects it from freezing rain or sleet.

From External Regulator (11" W.C. to 14" W.C. Pressure)

3" Minimum

Pipe Nipple Cap Tee Joint

Sediment Trap

Figure 23 - Gas Connection

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 27.

14

104059

Page 14
Image 14
Vanguard Heating VMH26TPA installation manual Connecting to GAS, Supply, Attaching Wood Base to Solid Floor

VMH26TPA specifications

The Vanguard Heating VMH26TPA is designed to provide efficient, reliable, and eco-friendly heating solutions for modern homes. This heating unit boasts a variety of advanced features and technologies that ensure optimal performance and comfort, making it a popular choice among homeowners.

One of the standout characteristics of the VMH26TPA is its high efficiency rating. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, this unit operates at a significantly lower cost compared to traditional heating systems. This means not only lower energy bills but also a reduced carbon footprint, making it a sustainable choice for environmentally-conscious consumers.

Moreover, the VMH26TPA employs innovative technologies that enhance user control and comfort. It comes equipped with a smart thermostat, allowing homeowners to adjust settings remotely using a smartphone or tablet. This feature enables precise temperature control, so users can ensure their home remains comfortable even when they are away.

The compact design of the VMH26TPA is another advantage. This unit is specially engineered to fit in smaller spaces without sacrificing performance. Its sleek and modern aesthetic also ensures that it can blend seamlessly with a variety of home decors, making it not just functional but visually appealing.

In terms of installation, the VMH26TPA features a streamlined process that is generally straightforward for professionals. This reduces the time and hassle typically associated with heating system installations. Additionally, the unit is built with durable materials that ensure longevity and reduce the likelihood of malfunction over time.

Noise levels during operation are minimal, thanks to Vanguard Heating's engineering innovations. This means homeowners can enjoy a quiet environment without interruptions from traditional heating noises.

Maintenance is made easy with the VMH26TPA, as it is designed to be user-friendly. Regular upkeep can be performed with basic tools, and Vanguard provides clear guidelines, ensuring that homeowners can keep the system in excellent working order without excessive effort or cost.

In summary, the Vanguard Heating VMH26TPA embodies efficiency, convenience, and durability. With its advanced technology, high efficiency rating, compact design, and user-friendly features, it provides an outstanding heating solution for homeowners looking to enhance their comfort while being mindful of their energy consumption. This makes it a strong contender in today's competitive heating market, appealing to a wide array of consumers.