OWNER’S MANUAL

INSTALLATION

Continued

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater.

Attaching To Wall Stud Method

For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching To Wall Anchor Method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 9.

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings.

IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

5.Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.

6.Insert mounting screws through bracket and into wall anchors.

7.Tighten screws until mounting bracket is firmly fastened to wall.

Figure 9 - Folding Anchor

Figure 10 - Popping Open Anchor Wings For Thin Walls

Placing Heater On Mounting Bracket

1.Locate two horizontal slots on back panel of heater.

2.Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Horizontal Slots

Stand-Out Tab

Mounting Bracket (attached to wall)

Figure 11 - Mounting Heater Onto Mounting Bracket

Installing Bottom Mounting Screws

1.Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 14).

2.Mark screw locations on wall.

3.Remove heater from mounting bracket.

4.If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 un- der Attaching To Wall Anchor Method. If installing bottom mounting screw into wall stud, drill holes at marked lo- cations using 9/64" drill bit.

5.Replace heater onto mounting bracket.

6.Place spacers between bottom mount- ing holes and wall anchor or drilled hole.

7.Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.

8.Tighten both screws until heater is firmly secured to wall. Do not over tighten.

Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 10 and 11).

Figure 12 - Installing Bottom Mounting Screws

Continued

104246

9

Page 9
Image 9
Vanguard Heating VN1800ITB, VN2550ITB Attaching Mounting Bracket To Wall, Placing Heater On Mounting Bracket

VN2550ITB, VN1800ITB specifications

The Vanguard Heating VN1800ITB and VN2550ITB are high-efficiency heating solutions designed to cater to the diverse needs of residential and commercial spaces. These units exemplify advanced technology, offering reliable and consistent warmth while prioritizing energy efficiency.

The VN1800ITB model is engineered to deliver a powerful heating capacity of 18,000 BTUs, making it suitable for medium-sized rooms. It boasts a sleek design that allows for seamless integration into various decor styles. One of the standout features of the VN1800ITB is its innovative variable-speed blower, which not only enhances comfort by maintaining even temperatures but also reduces energy consumption. The blower adjusts its speed based on demand, resulting in quieter operation and improved efficiency.

In addition, the VN1800ITB includes a state-of-the-art digital thermostat that enables precise temperature control. Users can easily program heating schedules, leading to further savings on energy bills. The inclusion of a high-quality air filter improves indoor air quality by trapping dust and allergens, making it an ideal choice for households with allergy sufferers.

On the other hand, the VN2550ITB offers an impressive heating capacity of 25,000 BTUs, making it suitable for larger areas. This model incorporates similar advanced features as its counterpart, including the variable-speed blower and digital thermostat. However, it also features enhanced insulation, which minimizes heat loss and increases overall efficiency. The VN2550ITB is equipped with advanced safety features, including overheat protection and a flame rollout switch, ensuring the unit operates safely even in demanding conditions.

Both models utilize cutting-edge combustion technology that maximizes warmth while minimizing emissions. This commitment to environmental responsibility not only helps users meet local regulations but also contributes to a greener planet.

In conclusion, the Vanguard Heating VN1800ITB and VN2550ITB combine performance, efficiency, and safety features in aesthetically pleasing designs. These heating units provide dependable warmth, programmable convenience, and a commitment to indoor air quality, making them a smart investment for those seeking effective heating solutions.