IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

3/8" NPT Pipe Nipple

Manual

Shutoff

Valve *

From

Gas Meter (4" W.C. to 10.5" W.C. Pressure)

3" Minimum

Pressure

Regulator

Heater

Cabinet

Ground Joint

Union

Tee Joint

 

 

 

 

 

 

 

 

Reducer

 

Test

Bushing to

 

Gauge

 

1/8" NPT

Connection *

 

 

 

1/8" NPT

 

 

Plug Tap

 

 

 

Tee

 

 

 

Joint

 

Sediment

Pipe

 

 

Trap

 

Nipple

 

 

 

Cap

 

 

 

CHECKING GAS CONNECTIONS

10

Figure 10 - Gas Connection

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See ACCESSORY, page 21.

!WARNING

Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

!WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

Continued

Page 10
Image 10
Vanguard Heating VN6A, VN12 installation manual Checking GAS Connections, Pressure Testing GAS Supply Piping System