Vanguard Heating VP1600D Operating Heater, Lighting Instructions, Models VP1600ITA and VP2200ITA

Models: VP1600ITA VP2200ITA VP1600D VP2600D

1 40
Download 40 pages 11.03 Kb
Page 18
Image 18
OPERATING HEATER

OPERATING HEATER

Models VP1600ITA and VP2200ITA

Continued

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information at the top of page 17.

2.Make sure manual shutoff valve is fully open.

3. Turn thermostat control knob on left side of heater clockwise ClockwiseLIGHTING INSTRUCTIONS to the

OFF position.

Thermostat Control Knob

Manual backgroundPILOT

OFF

HI

Ignitor Button

Plaque

Control Knob

1 Manual background

2

LO

3 Manual background

IGNITOR

4

18

Figure 17 - Thermostat Control Knob In The OFF Position

4.Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 17. If you don’t smell gas, go to the next step.

5.Turn thermostat control knob on left side of heater counterclockwise

Manual backgroundC-clockwiseto the PILOT position. Press in thermostat control knob for 5 seconds.

Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in thermostat control knob for 30 seconds. This will allow air to bleed from the gas system.

If thermostat control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.Keep thermostat control knob pressed in while pushing down and releasing the ignitor button. This will light pilot. If necessary, continue to press ignitor button until pilot lights.

If pilot does not light

turn thermostat control knob clockwise ClockwiseManual background to the OFF position

repeat steps 5 and 6

If pilot does not stay lit after several tries

refer to Troubleshooting, pages 26 through 29

contact a qualified service person or gas supplier

Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 20.

7.Keep thermostat control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one minute before lighting pilot again.

8.Turn thermostat control knob counterclockwise Manual backgroundC-clockwiseto the desired heating level. The plaque directly above the pilot should light.

101823

Page 18
Image 18