TO TURN OFF GAS TO APPLIANCE

OPERATING HEATER

Models VP1600ITA and VP2200ITA

Continued

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1. Turn thermostat control knob clockwise ClockwiseTHERMOSTAT OPERATION to the OFF position.

2. Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

1. Turn thermostat control knob clockwise ClockwiseMANUAL LIGHTING PROCEDURE to the PILOT position.

THERMOSTAT OPERATION

(Models VP1600ITA and VP2200ITA Only)

The thermostat measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing con- struction, installation location, room size, open air temperatures, etc.). Fre- quent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 18.

2.With thermostat control knob pressed in, strike match. Hold match to pilot until pilot lights.

3.Keep thermostat control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

20

101823

Page 20
Image 20
Vanguard Heating VP2600D To Turn Off Gas To Appliance, Thermostat Operation, Manual Lighting Procedure, Operating Heater