TROUBLE- | WARNING | |
SHOOTING | ||
If you smell gas | ||
Continued | • Shut off gas supply. |
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
| IMPORTANT: Operating heater where impurities in air exist may create odors. | ||||||||
| Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new | ||||||||
| carpet or textiles, etc., create fumes. These fumes may mix with combustion air and | ||||||||
| create odors. |
|
|
|
|
|
|
| |
| OBSERVED | POSSIBLE |
|
|
|
|
| ||
| PROBLEM | CAUSE | REMEDY |
| |||||
| Heater produces | 1. | Heater burning vapors | 1. | Ventilate room. Stop | ||||
| unwanted odors. |
| from paint, hair spray, |
| using odor causing | ||||
|
|
| glues, etc. See IMPOR- |
| products while heater is | ||||
|
|
| TANT statement above |
| running. | ||||
|
| 2. | Low fuel supply | 2. | Refill supply tank. | ||||
|
| 3. | Gas leak. See Warn- | 3. | Locate and correct all | ||||
|
|
| ing statement at top |
| leaks (see Checking Gas | ||||
|
|
| of page. |
| Connections, page 15). | ||||
|
|
|
|
|
|
|
| ||
| Heater shuts off in use | 1. | Not enough fresh air is | 1. | Open window and/or | ||||
| (ODS operates). |
| available. |
| door for ventilation. | ||||
|
| 2. | Low line pressure | 2. | Contact local propane/ | ||||
|
| 3. | ODS/pilot is partially |
| LP gas company. | ||||
|
| 3. | Clean ODS/pilot (see | ||||||
|
|
| clogged. |
| Cleaning and Mainte- | ||||
|
|
|
|
| nance, page 26). | ||||
|
|
|
|
|
|
| |||
| Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct all | ||||
| control knob is in OFF |
| ing statement at top |
| leaks (see Checking Gas | ||||
| position |
| of page. |
| Connections, page 15). | ||||
|
| 2. | Control valve defective. | 2. | Replace control valve. | ||||
|
|
|
|
|
|
| |||
| Gas odor during | 1. | Foreign matter between | 1. | Take apart gas tubing | ||||
| combustion |
| control valve and |
| and remove foreign | ||||
|
|
| burner. |
| matter. | ||||
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all | ||||
|
|
| ing statement at top |
| leaks (see Checking Gas | ||||
|
|
| of page. |
| Connections, page 15). | ||||
|
|
|
|
|
|
| |||
| Moisture/condensation | 1. | Not enough combus- | 1. | Refer to Fresh Air for | ||||
| noticed on windows |
| tion/ventilation air. |
| Combustion and Venti- | ||||
|
|
|
|
| lation requirements | ||||
TECHNICAL |
|
|
|
| (page 5) | ||||
You may have further questions about installation, operation, or troubleshooting. | |||||||||
| |||||||||
SERVICE | If so, contact DESA International’s Technical Service Department at |
| |||||||
5190. |
|
|
| 29 |
101823