BURNER FLAME PATTERN

INSPECTING BURNER

Continued

BURNER FLAME PATTERN

Figure 25 shows a correct burner flame pattern. Figure 26 shows an incorrect burner flame pattern.

Figure 25 - Correct Burner Flame Pattern

Bad Burner Pattern-Plaque GRH/OV 019

Figure 26 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 26

turn heater off (see To Turn Off Gas to Appliance, page 20 [models VP1600ITA and VP2200ITA] or page 24 [models VP1600D and VP2600D])

see Troubleshooting, pages 26 through 29

101823

25

Page 25
Image 25
Vanguard Heating VP1600ITA, VP2600D, VP1600D, VP2200ITA installation manual Inspecting Burner, Continued, Burner Flame Pattern