OPERATING HEATER (THERMOSTAT MODELS)

Lighting Instructions

15

OPERATING HEATER

THERMOSTAT MODELS (Continued)

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information, column 2 page 14.

2.Make sure equipment shutoff valve is fully open.

3. Turn thermostat control knob clockwise Clockwise to the OFF position (see Figure 22 or 23 for your model).

4.Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 2 page 14. If you don’t smell gas, go to the next step.

5.Turn thermostat control knob counterclockwise C-clockwiseto the PILOT position. Press in thermostat control knob for 5 seconds (see Figure 22 or 23 for your model).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in thermostat control knob for 30 seconds or more. This will allow air to bleed from the gas system.

If thermostat control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.Keep thermostat control knob pressed in while pushing down and releasing the ignitor button. This will light pilot. If nec- essary, continue to press ignitor button until pilot lights.

If pilot does not light

• turn thermostat control knob clockwise Clockwise to the

OFF position

repeat steps 5 and 6

If pilot does not stay lit after several tries

refer to Troubleshooting, pages 19 through 21

contact a qualified service person or gas supplier

Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 16.

7.Keep thermostat control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one minute before light- ing pilot again.

8.Turn thermostat control knob counterclockwise C-clockwiseto the desired heating level. For models, VP16T, VN18T, VP26T, and VN30T, the main burner should light. Set con- trol knob to any heat level between HI and LOW (see Fig- ure 25). For infrastat models, the plaque directly above the pilot should light.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor

 

 

Control

Button

PILOT

LO

Knob

 

OFF

 

 

HI

 

 

 

IGNITOR

 

 

Figure 22 - Control Knob In The OFF Position, Models VP16T, VN18T, VP26T, & VN30T

Plaque Control Knob

Ignitor Button

Thermostat

Control Knob

 

1

 

 

 

2

 

 

 

 

 

TOLIP

LO

 

 

 

 

 

FFO

 

 

 

HI

 

3

 

 

 

4

IGNITOR

 

 

 

 

 

Figure 23 - Thermostat Control Knob In The OFF Position, Models VP16IT, VN18IT, VP26IT, & VN30IT

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 24 - Pilot

 

 

Control Knob

VP16T

VP26T

VN18T

VN30T

 

 

 

 

PILOT

 

 

 

F

 

 

 

 

F

 

 

 

 

O

 

 

 

IH

LO

 

 

T

ILOP

LO

 

 

OFF

 

 

 

 

HI

 

 

 

Figure 25 - Burner Patterns

For morevisit www..com

107887

Page 15
Image 15
Vanguard Heating VN30T, VP26T, VP16T, VP22IT, VN18T, VN18IT, VP16IT, VN25IT installation manual Thermostat Models

VN18, VN18IT, VP16IT, VN25IT, VP26T specifications

Vanguard Heating offers a range of innovative heating solutions, including the VP16T, VP22IT, VN18T, VP16IT, and VP26 models. Each of these heaters is designed to provide efficient and reliable warmth for various spaces, making them suitable for both residential and commercial use.

The VP16T model is known for its compact size and powerful heating capabilities. It features an adjustable thermostat that allows users to maintain their desired temperature effortlessly. Designed for energy efficiency, the VP16T operates with minimal energy consumption while delivering consistent heat output. Its lightweight construction makes it easy to move and install in different areas as needed.

The VP22IT model expands on the VP16T's features, incorporating advanced technology for improved performance. It comes with a built-in timer function, allowing users to program their heating schedule. This feature enhances energy savings and convenience, as the heater can automatically turn on or off based on individual preferences. Additionally, the VP22IT includes a safety shut-off mechanism that activates in case of overheating, ensuring safe operation.

The VN18T is designed for versatile applications, featuring multi-directional airflow for optimized heating distribution. It is equipped with robust heating elements that provide quick warmth in a matter of minutes. This model is particularly popular for larger spaces due to its high heating capacity. The VN18T also includes a user-friendly digital control panel, making it easy to adjust settings.

The VP16IT combines the strengths of its predecessors, integrating smart technology for enhanced user experience. It features Wi-Fi connectivity, allowing users to control the heater remotely using a smartphone app. This model also supports voice command integration, making it compatible with smart home systems. Its sleek design adds a modern touch to any environment.

Lastly, the VP26 model offers the highest heating output among the Vanguard lineup. Tailored for large areas, it incorporates a dual-zone heating system that optimizes performance based on room size and heating requirements. Its advanced thermal insulation technology minimizes heat loss, contributing to efficiency and reduced energy costs.

In conclusion, Vanguard Heating's selection of VP16T, VP22IT, VN18T, VP16IT, and VP26 models features innovative technologies, safety measures, and user-friendly controls. These heaters are engineered to provide effective heating solutions that prioritize efficiency, convenience, and safety, making them a top choice for consumers seeking reliable warmth in any setting.