OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most fireplaces. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Fireplace burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Gas leak. See Warning statement

 

 

above

1.Open window and ventilate room. Stop using odor causing products while fire- place is running

2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)

Fireplace shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local propane/LP gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 18)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

above

 

ing Gas Connections, page 12)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

1.

Take apart gas tubing and remove

 

 

and burner

 

foreign matter

 

2.

Gas leak. See Warning statement

2.

Locate and correct all leaks (see Check-

 

 

above

 

ing Gas Connections, page 12)

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

lation requirements (page 4)

www.desatech.com

107156

21

For more information, visit www.desatech.com

Page 21
Image 21
Vanguard Heating VSGF28PVA, VSGF28PTC installation manual Gas leak. See Warning statement

VSGF28PTC, VSGF28PVA specifications

Vanguard Heating has made a significant mark in the heating solutions industry with its innovative models, the VSGF28PTC and VSGF28PVA. These units embody advanced technologies, reliable performance, and user-centric features that cater to both residential and commercial needs.

One of the standout characteristics of the VSGF28PTC and VSGF28PVA is their exceptional energy efficiency. Both models are designed to operate with a high Annual Fuel Utilization Efficiency (AFUE) rating, which ensures that more of the energy consumed is converted into usable heat. This not only helps in reducing energy bills but also contributes to lower carbon emissions, making these models an eco-friendly choice.

Both units feature a compact design that allows for easy installation in limited spaces, further enhancing their versatility. They are equipped with a two-stage gas valve that provides precise control over heating output, allowing users to enjoy consistent comfort throughout a variety of conditions. This technology helps maintain an even temperature while minimizing energy wastage.

Vanguard Heating has also integrated advanced safety features in these models. The built-in safety shutoff system will automatically turn off the unit in case of any detected malfunctions, giving users peace of mind. Additionally, these models incorporate flame rollout switches and pressure switches to ensure reliable operation and enhance overall safety.

Ease of use is another strong suit of the VSGF28PTC and VSGF28PVA. Their intuitive digital thermostats enable straightforward programming, allowing users to set heating schedules that suit their daily routines. This user-friendly interface is complemented by an easy-access filter that simplifies routine maintenance, ensuring optimal performance and extending the lifespan of the units.

Moreover, both models are designed for quiet operation, with sound-absorbing features that minimize noise, ensuring a comfortable indoor environment. For those in colder climates, the robust construction of these systems guarantees effective operation even in extreme temperatures.

In summary, Vanguard Heating's VSGF28PTC and VSGF28PVA present a winning combination of energy efficiency, advanced safety, user-friendly features, and quiet operation. These heating solutions promise reliability and peace of mind for anyone looking to enhance their indoor comfort while being mindful of energy consumption and environmental impact.