CR Series Woodburning Fireplaces

Chimney Requirements - Offset Installations

Chimney Flue Exit

 

 

Chimney

 

 

 

 

Section

 

 

 

 

Elbow

 

30°

 

 

 

 

Return

A

 

B

G

Elbow

 

 

 

 

 

 

 

 

30°

G

D

 

 

Offset

 

E

Rise

Elbow

 

 

 

 

C

6 FT.

 

30°

SKCS8

 

 

 

 

Support

 

 

Return

 

 

H

 

 

Offset

Elbow

 

 

 

 

H

 

 

 

30°

B

 

 

 

 

 

Offset

 

 

 

 

Elbow

 

 

Hearth Floor

 

 

Example 1

 

Example 2

 

Example 3

NOTE: G + H Cannot Exceed 20’

 

 

FP269CR

OFFSET

RISE

 

 

 

 

 

 

 

FP282

 

 

 

 

 

 

30˚ Elbow Offsets

 

 

 

 

 

 

 

 

 

 

 

1’

1¹⁄₂' 3’

4’

Chimney Support

Offset

Rise

 

 

 

 

 

 

 

 

 

 

0

0

0

0

0

3”

11”

 

 

1

0

0

0

0

8¹⁄"

20"

 

 

0

1

0

0

0

11¹⁄" 25¹⁄"

 

 

2

0

0

0

0

13¹⁄" 29¹⁄"

 

 

1

1

0

0

0

16¹⁄" 34¹⁄"

 

 

0

0

1

0

0

20¹⁄" 40³⁄"

 

 

2

1

0

0

0

21³⁄" 43¹⁄"

 

 

0

0

0

1

0

26¹⁄" 51¹⁄"

 

 

0

1

1

0

0

28¹⁄" 55¹⁄"

 

 

1

0

0

1

0

31¹⁄" 60¹⁄

 

 

0

1

0

1

0

34¹⁄" 65¹⁄"

 

 

0

0

2

0

0

37¹⁄" 70³⁄"

 

 

1

1

0

1

1

41¹⁄" 77³⁄"

 

 

0

0

1

1

1

45" 83³⁄"

 

 

0

1

2

0

1

47¹⁄" 87¹⁄"

 

 

0

0

0

2

1

51"

94"

 

Illustration Key

The following safety rules apply to offset installations. (The letters correspond with letters above):

A.Height of the chimney measured from the hearth to the chimney exit at top:

 

CR36L/R Series

Maximum:

90’0”

Minimum:

 

Without elbows

14’ 0”

With 2 elbows

15’ 0”

With 4 elbows

21’ 0”

B.Do not use more than four elbows per chimney.

Attach the straps of the top elbows to a structural framing member.

The first elbow of any pair does not have straps.

C.The chimney cannot be more than 30° from the vertical plane.

D.The maximum length of the angled run of the total chimney system is 20 feet. (G plus H cannot exceed 20 feet)

E.A chimney support (Model SKCS8) is required every 6 feet of angled run of chimney. Chimney supports are required at 30 feet and 60 feet of chimney height above the hearth also.

Determine the offset distance of your chim- ney arrangement from the centerline of the fireplace to the centerline of the chimney where it is to pass through the first ceiling.

NOTE: This offset distance may not be your full offset distance. See Examples 2 and 3.

0

1

1

1

1

53¹⁄"

98"

0

0

3

0

1

56¹⁄" 103¹⁄"

0

1

0

2

1

59¹⁄" 108¹⁄"

0

0

2

1

1

62¹⁄" 113¹⁄"

0

1

3

0

1

64¹⁄" 117¹⁄"

0

0

1

2

1

68¹⁄"

124"

0

1

2

1

1

70¹⁄"

128"

0

0

0

3

1

74¹⁄" 134¹⁄"

0

1

1

2

2

78" 140³⁄"

0

0

3

1

2

81"

146"

0

1

0

3

2

84" 151¹⁄"

0

0

2

2

2

87" 156¹⁄"

0

1

3

1

2

89¹⁄" 160¹⁄"

0

0

1

3

2

93" 166³⁄"

0

1

2

2

2

95¹⁄" 170³⁄"

0

0

0

4

2

99¹⁄" 177³⁄"

0

1

1

3

2

101¹⁄" 181³⁄"

0

0

3

2

2

104¹⁄" 186¹⁄"

0

1

0

4

2

107¹⁄" 191¹⁄"

0

0

2

3

2

110¹⁄" 196³⁄"

0

1

3

2

3

114" 203¹⁄"

0

0

1

4

3

117³⁄" 209³⁄"

0

1

2

3

3

120" 213¹⁄"

0

0

0

5

3

123³⁄"

220"

Fig. 3 Chimney system requirements.