Vermont Casting DVR28IN Rear Wall Installation Twist Lock Pipe, Step, the vent or elbow. STEP

Models: DVR28IN

1 28
Download 28 pages 20.76 Kb
Page 12
Image 12
Rear Wall Installation

Vermont Castings DVR28 Direct Vent Gas Fireplace

Rear Wall Installation

Twist Lock Pipe

STEP 1

Locate vent opening on the wall. To locate hole center consult with appropriate fireplace dimensions, Page 4. Frame as shown below.

Combustible Walls (Fig. 17): Cut a 10³⁄”H x 9³⁄” W (264 x 240 mm) hole through the exterior wall and frame as shown.

Noncombustible Walls (Fig. 17): Hole opening must be 7¹⁄” (190 mm) in diameter.

Zero clearance sleeve is only required for combustible walls.

STEP 2

Measure wall thickness and cut zero clearance sleeve parts to proper length (MAXIMUM 12”/305 mm). Assem- ble sleeve and attach to firestop with #8 sheet metal screws (supplied). (Fig. 18)

STEP 3

Measure the horizontal length requirement for the vent- ing including a 2” (51 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51 mm). (Fig. 15 or 16)

Vent Opening for Combustible Wall

9³⁄

(240mm)

Adjustable

Max. Length

Zero Clearance

12” (305mm)

Sleeve

 

 

#8 Screws (2)

#8 Screws

 

(2)

#8 Screws

 

(2)

Firestop

 

Adjustable Zero Clearance Sleeve

ZCS101

Fig. 18 Adjustable zero clearance sleeve.

STEP 4

Install the 4” (102 mm) vent to the appliance collar and secure with three (3) sheet metal screws. Install the 7” (178 mm) vent pipe to the appliance collar and secure with three (3) sheet metal screws. It is not necessary to seal this connection. If a 45° elbow is being used, attach the elbow to the appliance in the same manner then attach the venting to the elbow.

It is critical there is no downward slope away from the appliance when connecting

STEP 1 the vent or elbow. STEP 5

Guide the venting through the vent hole a you place the appliance in its installed position. Guide the 4” (102 mm) and 7” (178 mm) collar of the vent termination into the

10³⁄

(264mm)

Firestop

Fireplace Hearth

Top Tabs

Framing

Detail

Install provided firestop with zero clearance sleeve into framing opening after drywall or finish material is installed. Use the tabs for clearance locators top and bottom.

Opening for

Noncombustible Wall

7¹⁄

(190 mm)

outer ends of the venting. Do not force the termination. If the vent pipes do not align with the termination, remove and realign the venting at the appliance flue collars.

(Fig. 19) Attach the termination to the wall as outlined in the instruction sheet supplied with the termination.

Finished Wall

 

Firestop

Vent

 

 

Termination

Bottom Tabs

FP1751

Fig. 17 Locate vent opening on wall.

 the vent or elbow. STEP 5 Zero Clearance

Sleeve

FP1753

Fig. 19 Side view of final unit location.

12

20012301

Page 12
Image 12
Vermont Casting DVR28IN Rear Wall Installation Twist Lock Pipe, Vermont Castings DVR28 Direct Vent Gas Fireplace, Step