Vermont Castings, Majestic Products: DVR33
10004920
Troubleshooting – Honeywell Millivolt Valve
START CHECK
Gas Supply ON
Pilot lights with Piezo
igniter
Lockout has engaged. Wait 60
seconds and try again.
For spark at electrode while
depressing Piezo, 1/8" gap
to pilot hood needed.
All wiring connections
Replace Piezo igniter
Supply line hooked up
Shutoff valve OPEN
PILOT STAYS LIT
For air in the lines
Thermopile needs min. 325 mv
Adjust Pilot flame height
All wiring connections
Replace thermopile
Thermocouple needs min. 14 mv
PILOT LIGHTS MAIN
BURNER
Valve is turned ON
Wall switch is not turned ON.
Watch for grounded wires!
Thermopile needs min. 325 mv.
Plugged burner orifice
Defective Valve: Turn to Pilot;
meter should read greater than
100 mv. If not, replace.
SYSTEM OK
YES
NO
NO
NO
NO
YES
YES
YES
Window Frame Assembly Should be Removed Before Service Work