Vermont Casting LHEC30 Mantels, Framing & Finishing, Zero Clearance Applications, 10005360

Models: LHEC30 LHEC20

1 28
Download 28 pages 18.05 Kb
Page 5
Image 5
Mantels

Vermont Castings, Majestic Products LHE Natural Vent Insert

Mantels

When the unit is installed into a woodburning fireplace, the minimum distance the mantel can be placed above the fireplace is governed by local building codes applicable to woodburning fireplaces. Consult local authorities having jurisdiction for these clearances.

For applications requiring the use of a Zero Clearance Kit, the minimum height a mantel can be installed above the fireplace is 24" (610mm) from the top of the upper louvres. The maximum mantel depth is 8" (200mm). (Fig. 2)

The underside of the mantel will become warm. Use only finishes which are heat resistant and do not discolor.

 

24" Min.

 

(610mm)

 

FP1325

Fig. 2

Minimum mantel height above fireplace.

Framing & Finishing

For Zero Clearance Kit applications, it is important to determine the finished facing material before beginning to frame. This will allow for the thickness of the finishing material between the frame and the fireplace trim.

Similarly, consideration must be given to the 1" inch depth of the air inlet channel sitting on the fireplace base. Finishing material for the hearth should be flush with the top of the air inlet channel.

If the fireplace is installed at floor level a noncombus- tible hearth must extend a minimum 12" (305mm) in front of the fireplace.

If the fireplace is recessed into the wall and at least 12" (305mm) above floor level, no hearth is required.

The use of wallpaper adjacent to this fireplace is not recommended as high temperatures given off by this fireplace may adversely effect the binders in the adhesive used to apply the wallpaper.

 

 

37¹⁄₄" (946mm)

 

35"

 

(889mm)

 

 

 

Air Inlet Channel

 

 

27¹⁄₄" (692mm)

 

19¹⁄₈"

 

Drywall

(486mm)

 

 

Finish Wall

Decorative Trim Kit

 

 

FP1351

Fig. 3 LHE insert framing dimensions.

NOTE: Insulating around the fireplace will result in overheating and possible malfunctioning of the circulat- ing fan.

Zero Clearance Applications

An alternate air supply is recommended with this component.

For installation other than in existing woodburning fireplaces such as new construction or renovation projects, a Zero Clearance Kit must be used. The kit enables these inserts to be installed in combustible environments. Whenever using a Zero Clearance Kit, consideration must be given to the dimensions of the Zero Clearance Kit and the requirements of the Air Kit.

NOTE: If a Zero Clearance Kit is required for mod- els LHEC20/LHER20/LHEC30 Natural Vent Inserts, only the Vermont Castings, Majestic Products zero clearance kit HEZC is approved to be used. When using the HEZC with insert models LHEC20 or LHER20, the Trim Closure Kit, LHE20TCK, must also be installed.

10005360

5

Page 5
Image 5
Vermont Casting LHEC30, LHEC20 installation instructions Mantels, Framing & Finishing, Zero Clearance Applications, 10005360