Vermont Casting LHEC20 Gas Specifications, Gas Inlet & Manifold Pressures, Preparation, 10005360

Models: LHEC30 LHEC20

1 28
Download 28 pages 18.05 Kb
Page 6
Image 6
Gas Specifications

Vermont Castings, Majestic Products LHE Natural Vent Insert

Gas Specifications

 

 

 

Max.

Min.

 

 

 

Input

Input

Model

Fuel

Gas Control

Btu/h

Btu/h

LHEC20RN

Natural Gas

Millivolt Hi/Lo

20,000

14,000

LHEC20RP

Propane Gas

Millivolt Hi/Lo

20,000

15,000

LHEC20RFN

Natural Gas

Comfort Control

20,000

14,000

LHEC20RFP

Propane Gas

Comfort Control

20,000

15,000

LHER20RN

Natural Gas

Millivolt Hi/Lo

20,000

14,000

LHER20RP

Propane Gas

Millivolt Hi/Lo

20,000

15,000

LHEC30RN

Natural Gas

Millivolt Hi/Lo

30,000

21,000

LHEC30RP

Propane Gas

Millivolt Hi/Lo

30,000

22,500

LHEC30RFN

Natural Gas

Comfort Control

30,000

21,000

LHEC30RFP

Propane Gas

Comfort Control

30,000

22,500

 

 

 

 

 

Gas Inlet & Manifold Pressures

 

Natural

LP

Minimum Inlet Pressure

5.5" W.C.

11.0" W.C.

Maximum Inlet Pressure

14.0" W.C.

14.0" W.C.

Manifold Pressure

3.5" W.C.

10.0" W.C.

 

 

 

Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the unit and replace any part of the control which has been under water.

These gas inserts are approved for installation in solid fuel burning masonry or zero clearance fireplaces.

Preparation

Before beginning, remove glass door and logs from unit. Also check to make sure there is no hidden damage to the unit. Take a minute and plan out the gas,venting and electrical route. It is best to start with the gas line first followed by the chimney liner. (Refer to Page 9)

Gas Line Installation

When purging the gas line, the front glass must be removed.

If gas piping from the source to the heater location has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size.

The gas pipeline can be brought in through the rear or the base of the heater.

NOTE: The gas line connection can be made of either properly tinned 3/8" copper tubing, 1/2" rigid pipe or an approved flex connector then reduced to 3/8" to the heater. Some municipalities have additional local codes, it is always best to consult your local authority and the CSA- B149.1 installation code.

U.S. Installations consult the current National Fuel Gas Code, ANSI Z223.1

Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.

LHEC20 / LHER20 / LHEC30

Certified To

ANSI Z 21.88-2002 / CSA 2.33-2002

Vented Gas Fireplace Heaters

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

When using copper or flex connector, use only approved fittings. Always provide a union when using black iron pipe so the gas line can be easily disconnected for burner or fan servicing. See gas specifications for pressure details and ratings. NOTE: If flex connector is used, it must be kept inside of the heater.

 

1/2" Gas Supply

 

1/2" x 3/8" Shut Off Valve

 

3/8" Nipple

 

3/8" Union

 

3/8"

 

Nipple

FP297

 

Fig. 4

Typical gas supply installation.

6

10005360

Page 6
Image 6
Vermont Casting LHEC20 Gas Specifications, Gas Inlet & Manifold Pressures, Preparation, Gas Line Installation, 10005360