1 Listing and Code Approvals
A. Appliance Certification
The Gas Log Hearth Kits have been tested and listed in the U.S. in accordance with ANSI Z21.84‑2003 (Gas Log Set). They have been listed by OMNI Test Labs for installation and operation in the United States and Canada as described in these Installation and Operating Instructions. All components are UL, OMNI or CSA safety certified.
Check with your local building code agency prior to installing this appliance to ensure compliance with local codes, including the need for permits and
B. Table 1
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
WARNING
Fire Risk
Exhaust Fumes Risk
•Do NOT use this appliance as a
The flue must be permanently open. Refer to Table 1.
Product |
| 18” | 24” | |
|
|
|
| |
Inlet BTU | Nat. | 67,000 | 68,000 | |
Max. Inlet Pressure | Nat. | 10.0 / .052 | 10 / .052 | |
IN. WC / KPa |
|
|
| |
Min. Inlet Pressure IN. | Nat. | 3.5 / .018 | 3.5 / .018 | |
WC / KPa |
|
|
| |
Orifice Size | Nat. | (#28) | (#26) | |
In. |
|
|
| |
Minimum Fireplace | Front | 33 | 38 | |
Rear | 20 | 26 | ||
Opening Size | ||||
Depth | 15 | 15 | ||
In. / cm | ||||
Height | 21 | 21 | ||
| ||||
Min. Vent Opening in |
| 39 / 251.6 | 48 / 309.7 | |
Square In. / cm |
|
|
| |
|
|
|
|
These Hearth/Log Kits are for use with all CFM Factory built fireplaces.
20012914 7/05 Rev. 0