4 | Installation Instructions |
| ||
|
|
| ||
| For Use With All Other Fireplaces | |||
A. Damper Stop: |
|
| ||
For Use with BR, BC, SR, SC, TF and TL Series CFM | The Damper Clamp provided keeps your damper from ac- | |||
Corporation Fireplaces | cidentally closing during operation of your set. This Damp- | |||
This Damper Stop is designed to work on all CFM Corpora- | er Clamp must be installed onto your Damper at all times. | |||
NOTE: The damper clamp is designed to hold the damper | ||||
tion BR, BC, SR, TF and TL series fireplaces. For all other | ||||
plate open 3 inches. However, the damper must be fully | ||||
fireplaces, refer to note bellow. | ||||
open when the log set is in operation. | ||||
When installing a decorative gas appliance in a fireplace, | ||||
Install the Damper Clamp onto the edge of the damper plate. | ||||
some local codes require this Damper Stop to be used so | ||||
Attach by securing the bolt provided to the damper plate with | ||||
the Damper will not close completely. To install the Damper | ||||
an adjustable wrench. (Fig. 3) | ||||
Stop: | ||||
If the Damper Clamp does not fit, drill a ¼” hole onto the | ||||
The Damper Locking Bracket is already installed on all BR, | ||||
damper plate and install an anchor bolt with a nut, at a 90 de- | ||||
BC, SR, TF and TL fireplaces. Locate the Damper Locking | ||||
gree angle, so that the damper plate will remain fully open. | ||||
Bracket on the left side of the fireplace’s Combustion Dome. | ||||
The proper finished installation of the Damper Clamp is | ||||
(Fig. 1) | ||||
With the Damper open, align the two slots on either side | shown in Figure 4. If the bolt fails to block the damper in | |||
an open position, the damper should be removed from the | ||||
of the | ||||
chimney. | ||||
on the angled portion of the Damper Locking Bracket. At- | ||||
To check your vent for proper drafting: Light a tightly rolled | ||||
tach the Damper Stop with the Screws provided, as shown | ||||
in Figure 2. | newspaper on one end and place it at the inside front edge | |||
NOTE: Some of the early fireplace units may not have the holes in | of the fireplace. Observe the smoke and be sure the vent | |||
is properly drawing it up the chimney. If the smoke is drawn | ||||
the end of the Damper Locking Bracket. If this is the case, use the | ||||
back into the room, extinguish the flame and remove any ob- | ||||
Damper Stop as a template to drill two (2) 1/8” holes in the Damper | ||||
struction until proper venting is achieved. If that fails, check | ||||
Locking Bracket to mount the Damper Stop. | ||||
|
| with a qualified chimney sweep. |
Damper Locking Bracket | DamperPlate |
|
Figure 1
Damper Locking Bracket
DamperPlate
Damper Clamp
Figure 3
Damper Stop | 20012914 7/05 Rev. 0 | Figure 4 |
Figure 2 |